User Manual
8
Read the safety instructions carefully and follow the 
advice. Keep these instructions in case you need them 
later.
The product you just have bought complies to all 
european and national qualifications with respect to 
the specified LVD (Low Voltage Directive) and Electro 
Magnetic Compatibilty (EMC) (89/336/EEG)
SPECIFICATIONS
Product  Barite 60
Article number  111P
Power  3W AC/DC 12V
Luminous flux  230 lm
Light colour  3.000K
Average lifetime  25.000
On/off 10.000
Dimensions (h x Ø)  575 x 65 mm 
Protection class  IP44 
Ambient temperature  -20 °C to 50 °C
Cable length  1m
Dimmable No
Light source  Replaceable
PACKAGING CONTENT
[Figure A] 
1  Fixture Barite 60
2 Ground spike
3 Screw
4 Screw
5 Plug
6 Lightpro connector
7 Hex key
 Check if all parts are present in the packaging. For 
questions about parts, service, and any complaints or 
other remarks, you can always contact us. 
E-mail: info@lightpro.nl.
INSTALLATION
[Figure B]
Remove the screws [8] from the fixture [1] using the 
included hex key [7].
[Figure C]
Haal de voet [9] uit het armatuur [1]Remove the base [9] 
from the fixture [1].
OPTION 1: Placement in the ground
[Figure D]
Fasten the spikes [2] to the base [9] with the included 
screws [3].
[Figure E]
Place the base [9] in the fixture [1].
[Figure F]
Put the screws [8] back in the fixture using the hex key 
[7]. Place the fixture in the ground.
OPTION 2: Placement on a fixed underground
[Figure G]
Mount the base [9] on the underground using the 
included screws [4].
 If necessary, drill holes in advance and use the 
included plugs [5]
[Figure H]
Place the fixture [1] on the base [9].
[Figure I]
Put the screws [8] back in the fixture using the hex key [7].
REPLACEABLE LIGHTSOURCE
Proceed as follows in order to install or change the light 
source:
1  Turn the power off.
2 Let the light source cool down for at least 5 minutes.
3 Replace the light source, bearing the following points 
in mind:
•  Only replace the light source by an identical model 
with the same specifications.
•  When (re)assembling, ensure that the parts are dry 
and clean.
4 Turn the power back on.
Proceed as follows if the lamps do not light after you 
have followed the above instructions:
1  Turn the power off.
2 Check whether all plugs have been connected properly.
3 Check the light source(s) and replace them if 
necessary.
4 Check the transformer and the fuse (if applicable, and 
have them circuit-tested if necessary).
5 Check whether cables have been damaged.
6 Turn the power back on.
MANUAL AND SAFETY INSTRUCTIONS