User Manual
   Page 4  of 10 
 AB-0602A ARCHITECTURAL BALLAST DRIVER 
 Version 0.10  OWNERS MANUAL   07/05/2012 
www.lightronics.com 
Lightronics Inc.  509 Central Drive  Virginia Beach, Va  234354    757 486 3588
SIMPLE REMOTE CONNECTIONS 
Scenes 1 - 8 (stored in the AB-0602A) may be used 
by simple remotes. A BLACKOUT function may 
also be accessed. A simple remote is any switch that 
can provide a momentary contact closure which can 
be applied to a specific pin on the AB-0602A simple 
remote controls connector. 
See the 
CONTROL SIGNAL CONNECTIONS
diagram for specific connection details. The three 
COM
 (commons) pins are electrically tied together. 
A SIMPLE REMOTE COMMON is routed to the 
remote switch. When the switch is operated the 
closure brings the common back to the applicable 
pin 
(SW1 - SW8)
 on the simple remote controls 
connector in the AB-0602A. Contact SW9 is the 
BLACKOUT. Almost any available low voltage 
wire may be used since these connections are just 
contact closures. 
Multiple simple remotes may be used. Additionally  
multiple AB-0602A units may be chained to one or 
more simple remotes. 
An example remote of switch operation using a 
Lightronics APP01 switch is shown below. It can 
activate scene 1 and invoke a blackout. 
OPERATION 
SETUP AND OPERATING CONFIGURATION 
All operating functions and settings for the AB-
0602A are menu controlled using the LED Display 
and the 4 buttons located below it on the control 
circuit board. 
FACTORY DEFAULT CONFIGURATION 
The AB-0602A is supplied with a factory default 
setup configuration. The unit may be reset to this 
condition by keeping the SELECT button held 
down while power is applied. The display briefly 
shows 
FACt
 while the reset is being performed.  
The AB-0602A is set as follows when a reset is 
performed: 
1.  The DMX pack address (
PACA
) will be set to 
  DMX address 1 (
P001
). 
2.  Softpatch is set to DMX addresses 1 - 6 
3.  Dropout trip points are set to 35 (14%). 
4.  All channels curves are set to 
LED1
. 
5.  The architectural ID 
(ArCU)
 is set to 
00.
DISPLAY STATUS INDICATORS 
The LED display shows a dot near the upper left 
corner when a valid DMX signal is being received. 
MENU ACCESS AND USE 
Hold the MENU/NEXT button down for aprox. 5 
seconds to gain access to the complete menu system. 
If there is no button activity for 1 minute while 
inside the menus then the unit will revert back to the 
normal display (
PACA
). 
To exit from anywhere in the menus - Hold down 
MENU/NEXT for aprox. 5 seconds. The unit will 
revert back to the normal display (
PACA
). 
A menu/display operation flow diagram is provided 
at the back of this manual. 
CAUTION 
REMOVE ALL POWER FROM THE AB-0602A 
BEFORE MAKING OR CHANGING SIMPLE 
REMOTE CONNECTIONS. 
PACA
MENU 
NEXT 
SELECT
DMX VALID
SIMPLE REMOTE 