User Manual
   Page 7  of 10 
 AB-0602A ARCHITECTURAL BALLAST DRIVER 
 Version 0.10  OWNERS MANUAL   07/05/2012 
www.lightronics.com 
Lightronics Inc.  509 Central Drive  Virginia Beach, Va  234354    757 486 3588
CREATING AND SAVING SCENES 
Scenes to be activated by an AB-0602A must first be 
created and stored (recorded) in the unit. Scene 
recording stores the current intensity levels of all six 
channels in the unit regardless of how they were set. 
Intensity levels for a scene can be set using only the 
dimmer or by operating the unit with a DMX 
console. Each scene created has an associated user 
settable fade time. 
A universal BLACKOUT scene (all channels OFF) 
is also available. It appears as scene number 00 in 
the menus. The blackout scene has a user settable 
fade time. 
TO RECORD A SCENE 
Set the intensity for each channel in the unit to the 
desired brightness. 
Hold MENU/NEXT for aprox. 5 seconds to access 
the menus. The display will show 
dSET
. 
Push  MENU/NEXT until the display shows 
SYSt
. Push SELECT. The display will toggle 
between 
CnFG 
and the currently selected control 
source. 
Push MENU/NEXT until the display toggles 
between 
ScEn
 and the 
00
 (scene 00). 
Use and to change the scene number. Then 
push SELECT to record the intensity levels. 
The menu will advance to allow you to set the fade 
time for that scene. The display will toggle between 
FAdE and the current fade time (seconds). 
Use and to change the time. Then push 
SELECT to save the setting. 
The display will revert to the scene number selection 
menu. If you are operating with a DMX console you 
can change the channel levels and record to another 
scene. If operating in local mode you will have to 
exit from the menus to set new channel intensities. 
Hold MENU/NEXT for aprox. 5 seconds to exit 
from the menus. 
MAINTENANCE AND REPAIR 
FUSE REPLACEMENT 
REMOVE ALL POWER TO THE UNIT BEFORE 
REPLACING FUSES 
The internal electronic circuitry is protected by a 
1/2 Amp, 250V, 1 1/4" X 1/4", fuse. Replace the 
fuse ONLY with a with the same type and rating.  
The 
DIMENSIONS AND LOCATIONS
 diagram 
shows the fuse location. 
Each dimmed 120VAC output circuit has a 
replaceable 1 Amp, 250V, 5mm X 20mm fuse.  
Replace the fuse ONLY with the same type and 
rating. The 
DIMENSIONS AND LOCATIONS
diagram shows the fuse locations. 
INTERNAL SERVICE 
Internal service on the unit by other than Lightronics 
authorized agents will void the warranty. 
If service is required, contact the dealer from whom 
you purchased the dimmer, or Lightronics Service 
Department, 509 Central Drive, Virginia Beach, 
VA 23454. Tel: 757 486 3588. 
ScEn
 00
FAdE
 00
DANGER 
RISK OF FIRE 
DANGER 
RISK OF ELECTRIC SHOCK 