4. INSTALLING AND WIRING ELECTRICAL
POWER
There are two methods of providing power for the TOPCAT.
1. New Construction Installations: Connect directly to the buildings mains AC
power.
2. Retrofit situations: Can either wire to the building mains or order the optional
power extension cable (DCPEX-NA).
SUPPLY POWER TO THE SELECTED LOCATION
WARNING!
USE A CERTIFIED ELECTRICIAN FOR POWER CONNECTIONS.
The TOPCAT System uses standard 100 – 240VAC power. Obtain the services
of a certified electrician when supplying and connecting power to the TOPCAT
chassis. Be sure electrical installation complies with local building codes.
Improperly installing and /or connecting power to the system may result in
Equipment Damage, serious injury and/or Death.
When routing power to the TOPCAT, avoid interference with lighting and other
noise possibilities.
CAUTION:
These servicing instructions are for use by qualified service personnel only. To
reduce the risk of electric shock do not perform any servicing other than that
contained in the operating instructions unless you are qualified to do so.
Wire AC power to the TOPCAT as follows:
a. Turn off the current at the main breaker. Attach the electrical wiring to the
TOPCAT Ceiling Module as shown
b. Find the electrical box hole on the TOPCAT back can. Insert the mains
electrical wire through the hole.
c. Find and open the front panel door on the TOPCAT.
d. Remove the lid to the internal electrical box
e. Attach the ground wire to the grounding lug provided. Attach the remaining
two wires to the terminal block screws adjacent to the internal power wires.
f. Replace the lid on the electrical box and turn the electrical current on at the
main switch.
Green Green
Brown
Light Blue
TO
POWER
SUPPLY
100VAC