User's Manual

Table Of Contents
Technical Description & Configuration Guide Status Window
LigoWave Page 32
The main window in the Web GUI is the status window, which shows all the main system parameters,
and, in case of failure or any other problem, it tints a specific parameter in red.
To better understand what is exactly shown in the status window, we will go through every field of the
status window.
1. Shows the name of this LigoPTP 24 FODU, its IP address, serial number and uptime since the
last restart. If uptime is displayed in red, the connection to LigoPTP 24 management port was lost;
2. Shows the firmware version this LigoPTP 24 FODU is currently using;
3. Logout button allows ending the current Web GUI management session and logging in as a
different user if necessary. After pressing the button, you are automatically redirected to the login
page;
4. The tree of Web GUI sections;
5. Shows short summary of the main operational parameters of local and remote system.
Rx level (or RSL) at both ends must not differ significantly from the previously calculated
value.
Modulation indicates which modulation mode is used. For better operation the same
modulation must be set at both ends.
Radial MSE is explained below in the chapter Radial MSE.
Status Window