Alarm
ID
Group
ID
Alarm-Event name
Description
13
13
No data from main PSU ADC
No data from the main PSU ADC
14
14
Main supply voltage failure
Main supply voltage is out of defined
range
15
15
Main supply current failure
Main supply current is out of defined
range
16
16
Main supply power failure
Main supply power is out of defined
range
17
17
No data from power supply
ADC
No data from ADC connected via I2C
interface
18
18
1,2V failure
Power supply voltage out of defined
range
19
18
1,5V failure
Power supply voltage out of defined
range
20
18
3,3V failure
Power supply voltage out of defined
range
21
18
5,0V failure
Power supply voltage out of defined
range
22
18
Permanent 7,5V failure
Power supply voltage out of defined
range
23
18
Switchable 7,5V failure
Power supply voltage out of defined
range
24
18
12,0V failure
Power supply voltage out of defined
range
25
18
-5,0V failure
Power supply voltage out of defined
range
26
19
No data from RADIO
No data from radio (for future
compatibility)
27
20
Rx level alarm
Rx alarm level is out of defined range
28
21
Tx PLL error alarm
Tx PLL failure
29
22
Rx PLL error alarm
Rx PLL failure
30
23
No data from MODEM
No data from MODEM connected via
UART interface
31
24
Acquire status alarm
Modem acquire failure status
32
25
Last acquire error status
Modem last acquire failure status
33
26
Radial MSE
Radial MSE is out of defined range
34
27
LDPC decoder stress
LDPC decoder stress is out of defined
range
35
28
ACM profile was changed
ACM profile was changed
36
29
RX carrier offset
Error in Rx carrier offset
37
30
No data from modem
temperature sensor
No data from modem temperature
sensor
38
31
Modem temperature fault
Modem temperature is out of defined
range
39
32
ATPC Tx power correction
was changed
ATPC Tx power correction was changed
40
33
Rollback initiate system CPU
restart ==>
System restart was called by rollback
[Only rising]
41
34
System CPU reset was WDT
initiated ==>
System restart was called by watchdog