User's Manual

Table Of Contents
Technical Description & Configuration Guide Performance and Alarm Management
LigoWave Page 64
Figure 42 Alarm threshold configuration window
Alarm Management Commands
To manage alarms in command prompt, the commands are as follows:
Command
Description
Log show [<start line>]
The management controller maintains event log, - events
include configuration changes, management controller
restarts, and local site alarm changes.

log entries, the log entries are numbered, - entry with the

command can be followed up with an entry number to
display the latest 20 entries beginning from the entry
isplay

Log filter <alarm ID>
[<num>]
Filters event list by specific alarm ID. <start line> ; works

Log file <file name>
Makes event log file with specified filename.
Alarm stat
Lists alarm groups currently set.
Alarm list
Displays the list of all alarms, their group IDs and alarm
IDs.
Alarm groups
Displays the list of all alarms and their group IDs.