Datasheet
The graphs on the next page show which duty cycle can be expected compared to the load. The measurements for the
graphs have been made with an ambient temperature of 20°C. If the actuator is used in a higher ambient temperature the
duty cycle will decrease.
Test conditions for Duty Cycle.
The conditions of the tests carried out at LINAK A/S are as follows:
• Ambient temperature approx. 20°C.
• Actuator running at full stroke (between both end stop switches)
• Actuator running at max. recommended duty cycle
• Continuous operation 24 hours a day
• No vibrations
• Relatively clean enviroment (no extreme dust or dirt)
Please note that running the actuator in other conditions than the above mentioned may decrease or increase
the duty cycle of the actuator. Therefore it is recommended that the customer always tests the actuator in the
actual application, to ensure that the actuator fulfi lls the customers expectations.
Graphs for Duty Cycle
Other information:
• It is possible to have other stroke lengths. From 20 mm - 130 mm in steps of 3,75 mm.
• Winding isolation class F (155 degrees).
• Typical noise level dB (A) 55-57 measuring method DS/EN ISO 3746, actuator not loaded.
• The maximum working voltage for the LA12 (24 V motor) is 28 V and 14 V for the LA12 (12 V motor)