Product Info

Page 261 of 264
Studs for table placement
Studs for table placement
Back View
Side View
When placing CHL50 on table or shelf, 4 rubber studs on the back
add stability and friction to the charger/battery combination.
Charger mounting
When mounting CHL50 on wall, please use the two dedicated mounting holes placed in the charger body.
Mounting holes
Front View
CHL50 must be mounted by means of 2 screws (not supplied by LINAK):
Screw type: Diameter 4 mm/style: pan head or truss head.
Length and thread type depend on wall material.
Washer type: Optional 4 mm washer with max. 10 mm outer diameter.
The mounting screws for the control box and the charger must be tightened
with a maximum torque of 1 Nm.
Hanging on wall - Vertical Hanging on wall - Horizontal Laying flat on any surface
As long as the charger is mounted correctly, then the CHL50 complies to IPX4.
If the CHL50 is mounted incorrectly, then water will gather in the plug holes resulting in possible non-compliance with IPX4.
CHL50 can be mounted as shown on the pictures:
1) Batteries up, cable outlets downwards
2) CHL50 lying on the back, no difference if mains cable is up or down
3) IPX4 only if hanging upright
Recommendations - mounting
Studs for table placement