Deep discharge protection
The BA21 Li-Ion has a deep discharge protection to protect the battery life. The deep discharge protection is activated when the battery is discharged.
Charge the battery to exit the deep discharge mode. Ensure that the battery is sufficiently charged before use.
If the battery is completely discharged, the charging will be started at a very small rate to protect the battery. In this case the yellow LED will be flashing.
If the battery does not stop flashing and start charging normally within 12 hours (LED ON), the battery is defect and must be disposed according to
disposal instructions.
If any and all of the lithium ion batteries built into LINAK products are found to be defective under warranty, LINAK will provide a new product to the
OEM. LINAK explicitly disclaims all other remedies. LINAK shall not in any event be liable under any circumstances for any special indirect punitive
incidental or consequential damages or losses arising from any incident related to the inherent risk of thermal runaway in the lithium ion cell and any
use of LINAK products. Moreover, LINAK explicitly disclaims lost profits, failure to realise expected savings, any claim against our customer by a third
party, or any other commercial or economic losses of any kind, even if LINAK has been advised of the possibility of such damages or losses.
Transportation
The lithium ion batteries must be packed and transported according to applicable regulations. Always ask your local transportation provider how to
handle the transportation of lithium ion batteries.
If the clips are not engaged fully, the tab
will be sticking out as indicated.
Insert the battery connection cable into the battery port in the control box.
Ensure that it is fully connected.
Reconnect any actuator cables or hand
control cables to the correct ports.
Close the control box lid, ensuring that the
locking clips fully engage.
Reconnect the mains cable to the control box,
ensuring that the locking clip engages.
Turn on or reconnect the mains outlet.
Recommendations:
Charge the battery fully before first use.
Adhere to the battery storage temperature or else the lifetime and performance will be reduced.
Allow the battery to settle to room temperature before use or charging.
Adhere to the duty cycle or else the lifetime and performance will be reduced.
BA21 Li-Ion is neither intended for use in outdoor applications, pool environments nor other harsh environments.
Recharge the battery before storage if it has been completely discharged.
Unintentional use of the emergency button, for instance short activation and deactivation of the emergency button after operating the actuators, can
lead to an error indication of remaining battery capacity. The battery capacity will however be shown correctly approx. 20 seconds after activation of
the emergency button.
Only charge with applicable LINAK control boxes.