Installation Instructions

Page 189 of 194
16. WET Sheet (MEDLINE
®
CARELINE
®
)
The WET Sheet is an OpenBus™ product and is a part of the WET Detection solution.
The WET Detection solution consists of the WET Sheet, the MJB8 and a WET Sheet cable.
Recommendations
The WET Sheet is a wearing part which is not covered by the standard LINAK warranty
The WET Sheet warranty is valid until the product has been put into use
The WET Sheet is not a stand-alone article and must be included as part of an application e.g. the MJB8
The WET Detection will not detect liquid without conductivity e.g. demineralised water
The WET Sheet is not intended for outdoor use
The WET Sheet is not a life-supporting unit
Mechanical pressure on the WET Sheet can destroy the thread and connectors
It is recommended to change the WET Sheet cable after 500 connections
The sheet and connector must be placed properly to minimise the risk of bedsore
The WET Sheet connector is not to be exposed to direct moisture etc. urine or sweat.
Place the connector away from the user e.g. on the side of the bed
To ensure the right WET Detection functionality do not use layers on top of the WET Sheet, e.g. a turning sheet
The recommended temperature for washing is 60 °C. Washing at 85 °C is acceptable, however,
this will reduce the lifetime
Tumble drying at medium heat, however, line drying is recommended
The typical number of washing cycles is up to 50, but will depend on the washing conditions
The WET Sheet should be washed before use
17. QLCI2 (MEDLINE
®
CARELINE
®
)
The Quad Load Cell Interface 2 (QLCI2) for the
hospital and care segment is a scale system
accessory with weighing capabilities and Out of
Bed functionality.
The housing, makes the QLCI2 easy to mount
by unique slide-on brackets and has an IPX6
Washable DURA
TM
ingress protection.
The QLCI2 supports the LINAK OpenBus
TM
system offering a high level of customisation.
LINAK A/S delivers the OpenBus™ system only
and is not responsible for any products (i.e.
products from 3
rd
party suppliers) other than
LINAK products or the compatibility of such
products with the LINAK OpenBus™ system.
Usage
Operation temperature: + 5 °C to + 40 °C
Storage temperature: - 10 °C to + 50 °C
Relative humidity: 20% to 80% - non-condensing
Atmospheric pressure: 700 to 1060 hPa (3000 m)
Height above sea level: Max. 3000 meters
• Approvals IEC60601-1
ANSI/AAMI ES60601-1
CAN/CSA-22.2 No 60601-1
EN 45501 / OIML R76
EU type examination according to 2014/31/U
• Compatibility: All OpenBus
control boxes
• Flammability rating: UL V0
• Latex free: Yes