Recommendations:
Do not place load on the actuator housing and do prevent impact or blows, or any other form of stress to the housing.
Ensure that the cable lock is mounted correctly.
Ensure that the duty cycle and the usage temperatures for LA23 actuators is respected.
Ensure that the cable cannot be squeezed, pulled or subjected to any other stress.
The LA23 is not suitable for use in outdoor applications where it can be exposed to sun and rain.
If outdoor use cannot be avoided, it is very important that the LA23 is mounted in a position where it is well shielded. It is up to the customer to
provide the shielding. Furthermore, it will be good practice to ensure that the actuator is fully retracted in the “normal” position. The reason is that
there will be a vacuum inside the actuator if it is extended which over time can lead to water entering the actuator.
The item numbers for ordering the Cable Lock are:
Item number: 0231007 (light grey) for one cable lock (1 piece).
Item number: 0231037 (black) for one cable lock (1 piece).
Below you see an instruction in how to mount and remove the cable lock from LA23.
a) Mount a cable lock:
Push down until the cable lock clicks into place.
Step 1:
Insert e.g. a
screwdriver at
a 45 °C angle
as illustrated.
Step 2:
Turn the screw-
driver to release
the cable lock.
Step 3:
Now the cable
lock can be
removed by hand.
b) Cable lock removal
Note: When a cable lock has been removed, it is recommended to replace it with a new.