Electrical installation
To ensure maximum self-locking ability, please be sure that the motor is shorted when stopped. Actuators with integrated controller provide this
feature, as long as the actuator is powered.
When using soft stop on a DC-motor, a short peak of higher voltage will be sent back towards the power supply. It is important when selecting the
power supply that it does not turn off the output, when this backwards load dump occurs.
The power supply for actuators without integrated controller must be monitored externally and cut off in case of current overload.
Recommended fuse for actuators without integrated controller
Type Spindle
Pitch (mm)
Thrust max.
Push/Pull
(N)
Typical Amp. at full load
(A)
48 V 36 V 24 V 12 V
Recommended fuse
48 V 36 V 24 V 12 V
36080xxxxxxAxxxxH... 8 6800 - - - 17.0 - - - 40.0
36120xxxxxxAxxxxF... 12 2600 - - - 21.0 - - - 40.0
36120xxxxxxAxxxxG... 12 4500 - - - 20.7 - - - 40.0
36120xxxxxxAxxxxH... 12 6800 - - - 21.0 - - - 40.0
36200xxxxxxAxxxxF... 20 1700 - - - 22.0 - - - 40.0
36200xxxxxxAxxxxE... 20 500 - - - 20.0 - - - 40.0
36080xxxxxxBxxxxH... 8 6800 - - 8.0 - - - 20.0 -
36120xxxxxxBxxxxF... 12 2600 - - 10.4 - - - 20.0 -
36120xxxxxxBxxxxG... 12 4500 - - 10.2 - - - 20.0 -
36120xxxxxxBxxxxH... 12 6800 - - 10.3 - - - 20.0 -
36200xxxxxxBxxxxF... 20 1700 - - 10.3 - - - 20.0 -
36200xxxxxxBxxxxE... 20 500 - - 10.0 - - - 20.0 -
36080xxxxxxCxxxxH... 8 6800 - 8.0 - - - 16.0 - -
36120xxxxxxCxxxxF... 12 2600 - 8.0 - - - 16.0 - -
36120xxxxxxCxxxxG... 12 4500 - 8.0 - - - 16.0 - -
36120xxxxxxCxxxxH... 12 6800 - 8.0 - - - 16.0 - -
36200xxxxxxCxxxxF... 20 1700 - 8.0 - - - 16.0 - -
36200xxxxxxCxxxxE... 20 500 - 8.0 - - - 16.0 - -
36080xxxxxxDxxxxH... 8 6800 7 - - - 10.0 - -
36120xxxxxxDxxxxF... 12 2600 7 - - - 10.0 - - -
36120xxxxxxDxxxxG... 12 4500 7 - - - 10.0 - - -
36120xxxxxxDxxxxH... 12 6800 7 - - - 10.0 - - -
36200xxxxxxDxxxxF... 20 1700 7 - - - 10.0 - - -
36200xxxxxxDxxxxE... 20 500 7 - - - 10.0 - - -