User's Manual

Page 11 of 44
© 2020 LINAK A/S
Actuators with I/O Interface
Input/Output Specification Comments
Description I/O is a universal industrial interface which has
been developed by LINAK. I/O is a common
term used in the industry, to describe inputs
and outputs.
Flexibility is key when describing the possibili-
ties of an I/O actuator. A total of six wires are
customizable and this opens a world of intel-
ligent actuator control.
Supporting
PC tool for
Windows
Enhance your actuator experience with Actua-
tor Connect
TM
- Easy connection with Bluetooth
®
or a USB
cable*
- Flexibility in the development phase
- Utilize data to learn about the actuator perfor-
mance
* Cable must be purchased seperately (item no.
0367996)
Download your free version at www.linak.com
Power supply
Brown 24 or 48 VDC + (VCC)
Connect brown to positive
24 V ± 10 % - default current limit 13 A
48 V ± 10 % - default current limit 7.5 A
The actuator has an integrated h-bridge, and it
is therefore important not to change the power
supply polarity on the brown and blue wires.
Power supply GND (-) is electrically connected to
the housing
If the temperature drops below 0 °C, all default
current limits will automatically increase to 26 A
for 24 V and 15 A for 48 V
Blue 24 or 48 VDC - (GND)
Connect blue to negative
Digital or analogue input
Red Features available:
- Standard run - outwards
- Impulse run - outwards or both directions
(one wire)
- Servo (+)
- Proportional (+)
Standard run:
On/o voltages: > 67 % of V
IN
= ON and < 33 % of
V
IN
= OFF
Input current: 10 mA
Black Features available:
- Standard run - inwards
- Impulse run - inwards
- Servo (-)
- Proportional (-)
Digital output
Green Features available:
- End stop reached (outwards)*
- End stop zone reached (outwards)*
- Actuator running*
- Constantly high
- Single hall XOR
- Dual hall (A)
Digital outputs*:
The digital outputs are either active high or
active low, depending on the preferred signal
type.
- Output voltage min. V
IN
- 2 V
- Source current max. 100 mA
Yellow Features available:
- End stop reached (inwards)*
- End stop zone reached (inwards)*
- Actuator running*
- Constantly high
- Single hall XOR
- Dual hall (B)