Current cut-os should not be used as stop function! This might damage the actuator. Current cut-os
should only be used in emergencies!
Current cut-o limits are not proportional with the load curves of the actuator. This means that the cur-
rent cut-os cannot be used as load indicator.
There are tolerances on the spindle, nut, gear wheels etc. and these tolerances will have an inuence on
the current consumption for the specic actuator.
Analogue output or digital input
Orange Features available:
- Analogue feedback (+)
- Predened position 1
- Run condition
Light blue Features available:
- Analogue feedback (-)
- Predened position 2
Fixed wires
Violet Parallel communication
Violet wires must be connected together
The parallel drive function will support up to 8
actuators running simultaneously.
It is possible to run parallel with a single power
supply or run each actuator with separate
power supplies.
Please note: they must have the same potential
and the power supply GND must be connected
together (blue wires).
White Service interface The white wire is reserved for a service inter-
face (USB to PC) and has no functionality
during operation.
Grey Bluetooth
®
antenna The grey wire is used to strenghten the Blue-
tooth signal, allowing a stable wireless connec-
tion and has no functionality during operation.