• Current cut-os should not be used as stop function! This might damage the actuator. Current cut-os
should only be used in emergencies!
• Current cut-o limits are not proportional with the load curves of the actuator. This means that the cur-
rent cut-os cannot be used as load indicator.
• There are tolerances on the spindle, nut, gear wheels etc. and these tolerances will have an inuence on
the current consumption for the specic actuator.
Analogue output or digital input
Orange Features available:
- Analogue feedback (+)
- Predened position 1
- Run condition
Light blue Features available:
- Analogue feedback (-)
- Predened position 2
Fixed wires
Violet Parallel communication
Violet wires must be connected together
The parallel drive function will support up to 8
actuators running simultaneously.
It is possible to run parallel with a single power
supply or run each actuator with separate
power supplies.
Please note: they must have the same potential
and the power supply GND must be connected
together (blue wires).
White Service interface The white wire is reserved for a service inter-
face (USB to PC) and has no functionality
during operation.
Grey Bluetooth
®
antenna The grey wire is used to strenghten the Blue-
tooth signal, allowing a stable wireless connec-
tion and has no functionality during operation.