General indication of risk:
Installation of the device shall be performed by trained staff only, familiar with the safety requirements and risks. Check all relevant safety regulations and technical
indications for the specific installation place.
Prevent failures and protect persons against injuries and the device against damage.
The person responsible for the system must secure that:
• Safety and operation instructions are accessible and followed
• Local safety regulations and standards are obeyed
• Performance data and installation specifications are regarded
• Safety devices are installed and recommended maintenance is performed
• National regulations for disposal of electrical equipment are obeyed
Maintenance and repair
• Repairs on the device must be carried out by LINAK authorized persons only
• Only perform mounting described in this manual
During maintenance regard all safety regulations and internal operation instructions.
IECEx/ATEX
Mounting of ATEX cables
When changing the cables on a LINAK actuator, it is important that this is done carefully, in order to protect the plugs and pins. Before the new cable is
mounted, we recommend that the socket is greased with vaseline, to keep the high IP protection and ensure an easy mounting. Please be sure that the
plug is in the right location and fully pressed in before the cable lid is mounted.
Please note that if the cables are mounted and dismounted more than 3 times the plugs can be damaged. Therefore, we recommend that such cables are
discarded and replaced.
Also note that the cables should not be used for carrying the actuator.
We recommend to take some precaution and design the wire connection in a way, where the cable end is kept inside a closed, protected area to guarantee
the high IP protection.
3. Slide the cover onto
the actuator.
The torque of the
cover screw is
approx. 3.5 ± 0.3 Nm
TORX 25IP
1. Unscrew the cover and
remove the two blind
plugs.
2. Plug in the power
cable and/or the
signal cable.