User's Manual

Page 6 of 44
© 2020 LINAK A/S
During operation, please be aware of the following:
Listen for unusual sounds and watch out for uneven running. Stop the actuator immediately if anything unusual is observed.
Do not sideload the actuator.
Only use the actuator within the specified working limits.
Do not step or kick on the actuator.
When the equipment is not in use:
Switch off the mains supply in order to prevent unintentional operation.
Check regularly for extraordinary wear.
Classification
The equipment is not suitable for use in the presence of a flammable anaesthetic mixture with air or with oxygen or nitrous oxide.
Do not sideload the actuator.
When mounting the LA36 in the application ensure that the bolts can withstand the wear and that they are secured safely.
If irregularities are observed, the actuator must be replaced.
Recommendations
Do not place load on the actuator housing and do prevent impact or blows, or any other form of stress to the housing.
Ensure that the cable cover is mounted correctly. Use 3.5 Nm torque.
Ensure that the duty cycle and the usage temperatures for LA36 actuators are respected.
Ensure that the cable cannot be squeezed, pulled or subjected to any other stress.
Furthermore, it will be good practice to ensure that the actuator is fully retracted in the “normal” position. The reason is that there will be a vacuum inside the
actuator if it is extended which over time can lead to water entering the actuator.
If the actuator (without integrated controller) is mounted in an application where a mechanical stop prevents the endstop switches in the actuator from being
activated, the actuator must be equipped with an electrical safety device (current monitoring) or external limit switch.
Warnings