TECHNICAL SPECIFICATIONS -
POWER WAVE® 405M
INPUT AC VOLTAGE & DC OUTPUT
OUTPUT CABLES, CONNECTIONS AND LIMITATIONS
Product Ordering Input AC Rated DC Output Output Weight Dimensions
Name Information Voltage Amps/Volts/Duty Cycle Range with Cord HxWxD
5500//6600 HHzz
(continuous)
335500AA // 3344VV // 6600%% 1144..77xx1122..55xx
PPoowweerr 220000--222200// 33 PPhhaassee 2277..88**
WWaavvee KK 22336699--22 338800--440000// 332200AA // 3333VV // 6600%% AAMMPPSS 8866..55llbbss ((337733xx331188xx
440055MM 441155 11 PPhhaassee 55--442255 ((3377..44 kkgg)) 770066**))mmmm
5500//6600 HHzz
227755AA // 3311VV //110000%%
11 PPhhaassee
330000AA // 3322VV // 110000%% ** IInncclluuddeess
33 PPhhaassee hhaannddlleess
* Overall Length Including Handle, 21.6” (549mm) without handle.
Insulation Class 180 (H)
Select the output cable size based upon the following chart.
Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75°C rated:
DUTY CYCLE CURRENT LENGTH UP 61m (200 FT) 61-76m (200-250 FT)
100% 275 1/0 1/0
60% 350 1/0 2/0
POWER WAVE® 405M INPUT CURRENT
2. When operating on these inputs, the line cord should be changed to an input conductor of 6 AWG or larger.
1. Not rated is indicated by 4-x's in the box on the rating plate
Recommended Fuse Sizes Based On The U.S. National Electrical Code And Maximum Machine Outputs
Input 50/60 Hz Output Recommended
Voltage Phases 300Amps@ 350Amps@ Line Cord Size Fuse Size Notes
32Volts(100%) 34Volts(60%) AWG SIZES
200 3 41 48 6 80A Note 2
220 3 37 48 6 80A Note 2
380 3 23 28 8 50A
400 3 22 27 8 50A
415 3 22 26 8 50A
Voltage Phases 275Amps@ 320Amps@ Line Cord Size Fuse Size Notes
31Volts(100%) 33Volts(60%)
200 1 ---- ---- --- ----- Note 1
220 1 64 82 4 125A Note 2
380 1 44 55 6 80A Note 2
400 1 40 50 8 80A
415 1 38 48 8 80A