User's Manual

A-1
INSTALLATION
PLASMA 20
A-1
Weight
Including
Torch Cable
21 lbs.
9.5 kg.
INPUT - SINGLE PHASE
RATED OUTPUT
OUTPUT
RECOMMEND INPUT WIRE AND FUSE SIZES
REQUIRED AIR FLOW RATE REQUIRED AIR INLET PRESSURE
PHYSICAL DIMENSIONS
TECHNICAL SPECIFICATIONS - PLASMA 20
Standard Voltage
Duty Cycle
50% on 115V (15 Amp Branch)
40% on 115V (20 Amp Branch with 20 Amp Plug*)
Current
Range
10-20 Amps
AC Input
Voltage
at
50/60
Hertz
115V-1Ø
115V-1Ø
Maximum
Time-Delay
Circuit Breaker
or Fuse Size
20 AMPS
15 Amps
3 Conductor, #14 AWG
Type SJT or Hard Usage
Input Cord
Depth
16 in.
406 mm
Width
6 in.
152 mm
Height
12 in.
305 mm
Open Circuit
Voltage
310 VDC
For all plasma cutting applications
Based on U.S. National Electrical Code
Ambient Temperature 30
o
C or Less
Pilot Current
17 Amps
AMPS
15 A
20 A
1Ø Input Current at Rated Output
115/1/50/60Hz (15 Amp Branch)
115/1/50/60Hz (20 Amp Branch with 20 Amp Plug*)
115 V: 20A @ 50%
115 V: 26A @ 40%
3.5 cu. ft./min.
(100L/min.)
72.5 to 150 PSI
( 5 Bar TO 10.3 Bar)
20 A
15 A
Output
Plug Size
5-20P*
5-15P
*5-20P plug must comply with the standard for attachment plugs and receptacles, UL498.