Onthisscreen,theuser selects the gas mixture and
gasflowrate.SeeFigureB.28.Thecorrectgasmix-
tureandflowratemustbeenteredaccordingtothetol-
eranceeditor.Ifacceptablevaluesarenotentered,this
will be indicatedon a laterscreen and theuser may
have to go back and change the selection on this
screen.
Toselectthegasmixture,touchthedesiredicon.The
available gas mixtures are shown on the gas set-up
screenbelow.
To select the gas flow rate, touch the desired arrow
iconorthegasflowmeter.
!")
Selecting =5=CB takes the user back to the login
screen,withtheuser’snameremoved.
Selecting/19 takestheusertothepreviousscreen.
+ !"'(("'
'&"
#*&*+
Theusermustentertheproperweldingprocedureand
process settings, including wire feed speed, amper-
age,voltage,polarityandtrimwhereapplicable.See
FigureB.29.Asinthegassetupscreen,theusermust
entervalueswithintheacceptablerangeasgoverned
bythetoleranceeditor.Ifnot,theywillbenotifiedby
theincorrectweldsettingscreenwhenthegreencheck
settingsiconisselected.SeeFigures B.30 and B.31.
Theuserchangesthewirefeedspeedoramperageby
rotating the virtual wire feed speed/amperage dial.
Thedisplayabovethedialindicatesthesetting.
Theuserchangesthevoltagebyrotatingthevoltage
dial.Thedisplayabovethedialindicatesthesetting.
Someprocessesmaynotallowtheusertopre-setthe
voltage,inwhichcasethedisplaywillbeblank.
$# &(-' (#&
Change the polarity by rotating the virtual polarity
selectoricon.Theusercanselectthefollowing:
•AC
•DC+
•DC-
4 234/C:B B=:3@/<13A /@3 037<5 CA32 A33 B63
Default Weld Process Settings 7<1:C232 7< B67A
;/<C/:
Once the user has set the welding parameters, they
shouldselectthegreenchecksettingsicon.Iftheuser
hasenteredanysettingsoutsidetheacceptablerange
specified by the settings in the tolerance editor, the
incorrectweldsettingscreenwillappear.
*&(,