There is jitter, shake or wobble in
theHelmetdisplayandMonitor.
Theweldcouponimageis adiffer-
ent configuration than the physical
coupon.
When the check settings are acti-
vatedtheincorrectsettingsappear.
Holdingthegreenbuttonindoesnot
shut down the VRTEX
®
MOBILE.
Thisisnormal.
Thestudents’reportsarenotacces-
sible.
Thehelmetistoofarfromthework
piece. The further the helmet is
fromtheworkpiece the more jitter
theremaybeinthehelmetdisplay.
Local interference suchas fluores-
cent light, large metallic object
and/orhighfrequencies.
Either the wrong coupon is on the
stand or the wrong configuration
hasbeenselectedinthesoftware.
ThesettingsintheInstructorMode
areincorrect.
Holding the green button in does
not shut down the VRTEX
®
MOBILE.Thisisnormal.
USB notinfrontofmachine.
Movehelmetclosertoworkpiece.
Check for loose or faulty connec-
tions between the Helmet/Monitor
andtheVRTEX
®
MOBILEmachine.
SeetheWiringDiagram.
Make sure there are not other
objectsorfrequenciesthatareinter-
fering with the system. See the
Installation section.
Press the menu icon and select
‘changecoupontype’.Changethe
software selections so that the
images on the screen match the
hardwareyouareusing.
Makesureallofthe settingsinthe
tolerance editor are correct for the
process and parameters being
used. Check for the acceptable
rangesfortheLincolndefaults.
ToshutdowntheVRTEX
®
MOBILE
select Menu and then select
Shutdown.Thegreenbuttonisnot
usedforsystemshutdown.
The students’ reports can only be
savedviatheUSBportonthefront
oftheVRTEX
®
MOBILE.Plugina
USBmemorydeviceintothefrontof
the machine. If a USB memory
stick is not plugged into the USB
portorifthereisnotavailablemem-
oryontheUSBstick,the students’
reportswillnotbesaved.