Previous weld pass data is not
accessibleontheLASERscreen.
Theuserisnotsureofwhichtoler-
ancesettheyareusing.
The machine was shut down and
willnotturnbackonwhenthegreen
circularbuttonispressed.
The user cannot weld a second
pass.
The VR FCAW/GMAW and/or VR
SMAW(optional)device(s)location
doesnotcorrespondwiththeimage
shown in the FMD (Face Mounted
Display)device.
The VRTEX
®
MOBILE does not
startupwhenthegreencircularbut-
tonispressed.
“End Pass must be activated
beforestartinganewpass.Ifanew
couponisstartedthedatawillonly
be available for the first pass.
Again;“EndPass”mustbeselect-
edbeforeanewpassisstarted
The tolerance set displayed in the
tolerance editor is the one being
used.
Thetolerancesetcanalsoberead
fromthestudentreport.
Thesystemmaystillbeintheshut
downmode.
The joint configuration may be set
upforonepassonly.
The system may be located near
largemetalobjects.
Make sure the correct input power
isbeingappliedtothemachine.
Verify fused power switch isin the
Onposition.
Fusemaybefaulty.
Usethetouchscreentogotopass
number and change which pass
datayouarelookingfor.Notethat
someconfigurationsonlyhaveone
passcapabilities.SeetheLincoln
defaulttolerances.
Gototheinstructormodetochange
tolerances.Gototheloginscreen,
turn the key and select tolerances
toverifytoleranceset.
SeetheOperation section.
Wait 20 seconds, then press and
holdthegreencircularbuttonfor5
secondstostartthemachine.
Checkthetoleranceeditortoverify
the joint configuration allows for
multiplepasswelding.
Movethesystemtoasuitableloca-
tion.SeetheInstallation section.
Be sure to hold the green circular
buttoninforatleast5seconds.
Ifthegreencircularbuttondoesnot
stay on, removethe plug on lower
partofcase front. Press and hold
the green circular button and then
pressupthepushbuttoninsidethe
sheetmetal.SeeFigures E.1 and
E.2.