RETURNING THE TIMER TO THE FACTORY SETTINGS
Factory settings of each timer: 3sec. ON time, 30min. OFF time,
function ‘A’. No matter how you change the settings you can always
reset all settings to factory settings following these easy steps:
1. Disconnect the unit from the power supply.
2. Press and hold down (off/arrow down) and (TEST) buttons.
3. Connect the unit to the power supply.
4. Release the buttons after 'P' appears on the display.
5. Then 'A' appears on the display - do not press anything.
6. After a few seconds the unit will resume operation with factory
settings.
7. Change the presset ON and/or OFF times if required
OFF-LINE FILTER CLEANING
When the X-TRACTOR 3A is off, the signal to the solenoid valve is
controlled by an additional timer placed inside the cabinet. This timer
keeps the signal on for a certain period of time in order to run two or
three more cleaning cycles after the extraction unit is shut down
(OFF-line cleaning). Inside the filter container, there is a cover that
closes the inlet in order to avoid dust being blown out in the
duct/hose system.
FIGURE4
The timer is pre-set at the factory to the values in the following table.
Normally it is not necessary to adjust the timer.
OFF-LINE CLEANING SPECIFICATIONS
FUNCTION MULTI-FUNCTION
MOUNTING DIN-RAIL MOUNTING
DIMENSION .67” (DIN 43880)
RANGE 0.1 S X - 100 H
SUPPLY 24 - 240 VAC & 24 VDC
CONNECTION SCREW TERMINAL
I/O SIGNAL 8 A SPDT RELAY
TYPE SYM. RECYCLER, INTERVAL,
DELAY ON OP./REL.
I/O FUNCTION 7 FUNCTIONS
SETTING OF TIME
SETTING OF TIME RANGE
SETTING OF FUNCTION
TIMER VALUES
FUNCTION DELAYED OUT
TIME RANGE 60 SEC.
TIME 3 (TOTAL IS 3 X 60 SEC = 3 MIN.)
TIMER SPECIFICATIONS
INTERVAL (OFF) TIME .01 SEC. - 99 HR.
(note: check response time of your sole-
noid valve)
DISCHARGE (ON) TIME .01 SEC. - 99 HR.
(note: check response time of your sole-
noid valve)
SUPPLY VOLTAGE
110 – 240V AC/DC 50-60HZ (± 10%)
48 – 115V AC/DC 50-60HZ (± 10%)
10-48 V AC/DC 50-60HZ (± 10%)
CURRENT CONSUMPTION MAX. 7mA
OPERATING TEMPERATURE -40ºF to +140ºF (-40ºC to +60ºC)
ENVIRONMENTAL PROTECTION IP65 WHEN INSTALLED
CASE MATERIAL ABS PLASTIC FR GRADE
CONNECTION DIN 43650A - ISO 4400
INDICATOR DIGITAL DISPLAY
TIMER CERTIFICATIONS
CE YES
cULus YES
RoHS YES