Setting the DIP Switch
The DIP switch is labeled with an “ON” arrow showing
the on direction for each of the 8 individual switches in
the DIP switch (S1). The functions of the switch are
also labeled and set as described below:
Wire Drive Head Selection
The STT-10 control is set up for proper presettable
wire feed speed by setting S1 DIP switches (1 and 2)
as appropriate per the following examples for the head
specification and 10 Series wire drive external gear
selection being used:
For K1563-1,-3 or K1568-Series (10 Series Boom) or
K1560-1,-2 (10 Series Bench) with 35-500 IPM (0.89-
12.7 m/m) Low Speed Ratio
set S1 DIP Switch as fol-
lows: (initial factory setting)
For K679-1 (Synergic 7F Boom) with 50-770 IPM
(1.27-19.5 m/m) Low Speed Ratio
set S1 DIP Switch
as follows:
For K679-2 (Synergic 7F Boom) with 80-1200 IPM
(2.00-30.5 m/m) High Speed Ratio
set S1 DIP Switch
as follows:
Metric/English Wire Feed Speed Display
Selection
The STT-10 Control is set up for Wire Feed Speed dis-
play in Metric units (m/min.) or English units (IPM) by
setting S1 DIP Switch 4 (Labeled “M”):
S1 switch 4 OFF = IPM (as shipped)
S1 switch 4 ON = m/min
STT-10
OPERATING INSTRUCTIONS
Safety Precautions
Duty Cycle
The STT-10 models are rated at 60% duty cycle *
for a
maximum current of 600 amps.
* Based on a 10 minute time period (6 minutes on, and 4 minutes off).
STT-10 CONTROL DIP SWITCH
SETUP
Initial set up of the STT-10 control for the system
components being used and for general operator
preferences is done using an 8-pole DIP switch locat-
ed inside the STT-10 control box.
Setup DIP Switch Access
1) Shut off the input power to the STT-10 control by
turning off the power at the welding power source
it is connected to.
2) Remove the two screws on the top of the STT-10
control box door and swing the door down to
open.
3) Locate the 8-pole DIP switch, near the top left cor-
ner of the STT-10 Control P.C. board, labeled S1.
NOTE: Switch settings are only programmed during
input power-up restoration.
ELECTRIC SHOCK can kill.
Do not touch electrically live parts such
as output terminals or internal wiring.
Unless using cold feed feature
when inch-
ing with gun trigger, electrode and drive mech-
anism are “hot” to work and ground and could
remain energized several seconds after the
gun trigger is released.
Turn OFF input power at welding power
source before Control switch setup or
changing drive roll and/or guide tubes.
Welding power source must be connected
to system ground per the National
Electrical Code or any applicable local
codes.
Only qualified personnel should
operate this Equipment.
WARNING
Observe all additional Safety Guidelines detailed
throughout this manual.
Head
M 4
S R
S1
ON
S1
12 3456 78
L
Head
M 4
S R
S1
ON
S1
12 3456 78
L
Head
M 4
S R
S1
ON
S1
12 3456 78
L
Head
M 4
S R
S1
ON
S1
12 3456 78
L
Head
M 4
S R
S1
ON
S1
12 3456 78
L
Head
M 4
S R
S1
ON
S1
12 3456 78
L