User Guide

4-Step Trigger Mode Operation Selection
The STT-10 Control is set up for 4-Step Trigger mode
operation with or without weld current interlock by set-
ting S1 DIP switch 5 (Labeled “4”).
When 4-Step trigger mode is selected on the STT-10
keypad (See Keypad and Display Operation in this
section) S1 DIP switch setting determines the 4-step
trigger operation:
S1 switch 5 OFF = 4-Step with
current interlock
operation: (As shipped)
1) Closing Trigger initiates gas preflow time followed
by Run-in speed and strike voltage until arc strike
initiates welding.
2) Opening Trigger after welding arc is established
continues welding with weld current interlock.
(Breaking arc stops the feeder operation).
3) Reclosing Trigger continues welding but shuts off
current interlock function.
4) Reopening Trigger stops wire feed and initiates
burnback time, then gas postflow time.
S1 switch 5 ON = 4-Step without
current interlock
operation:
1) Closing Trigger initiates gas flow.
2) Opening Trigger initiates gas preflow timer followed
by Run-in speed and strike voltage until arc strike
initiates welding. (Trigger is released before arc is
struck, but once established breaking arc stops the
feeder operation).
3) Reclosing Trigger stops wire feed and initiates
burnback time, then gas postflow time.
4) Reopening Trigger stops gas flow if, or when, post-
flow time is over.
Security Mode Selection
The STT-10 Control is set up for Security Mode (See
“Security Mode” in this section) by setting S1 DIP
Switch 6 (Labeled “S”):
Head
M 4
S R
S1
ON
S1
12 3456 78
L
Head
M 4
S R
S1
ON
S1
12 3456 78
L
Head
M 4
S R
S1
ON
S1
12 3456 78
L
Head
M 4
S R
S1
ON
S1
12 3456 78
L
Head
M 4
S R
S1
ON
S1
12 3456 78
L
Head
M 4
S R
S1
ON
S1
12 3456 78
L
B-2
OPERATION
B-2
STT-10
Head
M 4
S R
S1
ON
S1
12 3456 78
L
Head
M 4
S R
S1
ON
S1
12 3456 78
L
S1 switch 6 ON = Security mode ON
S1 switch 6 OFF = Security mode OFF (as shipped)
Robotics Mode Selection
The STT-10 control is set up for Robotics Mode by
setting the S1 DIP Switch 7 (Labeled “R”). For
Robotics Interface Mode to operate, a K1561-1
Robotics Interface Module must be installed.
S1 switch 7 ON = Robotics mode ON
S1 switch 7 OFF = Robotics mode OFF (As shipped)
Range Lockout Mode Selection
The STT-10 control is set up for lockout of the Range
control (See Range Control in this section) by setting
S1 DIP Switch 8 (Labeled “L”).
S1 switch 8 ON = Range Lockout mode ON
When Range Lockout mode is selected, the Range
Key is disabled, and all previously selected ranges for
peak current, background current, and wire feed
speed are still enabled. To readjust the ranges, the
Range Lockout mode must be disabled.
S1 switch 8 OFF = Range Lockout mode OFF (As
shipped)