RETURN TO MAIN MENU IM788 SP-135 PLUS July, 2005 For use with machine Code Numbers : 10974 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thoughtful operation on your part. DO NOT INSTALL, OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL AND THE SAFETY PRECAUTIONS CONTAINED THROUGHOUT. And, most importantly, think before you act and be careful.
i i SAFETY WARNING CALIFORNIA PROPOSITION 65 WARNINGS Diesel engine exhaust and some of its constituents are known to the State of California to cause cancer, birth defects, and other reproductive harm. The Above For Diesel Engines The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. The Above For Gasoline Engines ARC WELDING CAN BE HAZARDOUS.
ii ii SAFETY ELECTRIC SHOCK can kill. 3.a. The electrode and work (or ground) circuits are electrically “hot” when the welder is on. Do not touch these “hot” parts with your bare skin or wet clothing. Wear dry, hole-free gloves to insulate hands. 3.b. Insulate yourself from work and ground using dry insulation. Make certain the insulation is large enough to cover your full area of physical contact with work and ground.
iii iii SAFETY WELDING SPARKS can cause fire or explosion. CYLINDER may explode if damaged. 6.a. Remove fire hazards from the welding area. If this is not possible, cover them to prevent the welding sparks from starting a fire. Remember that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas. Avoid welding near hydraulic lines. Have a fire extinguisher readily available. 6.b.
iv iv SAFETY PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suivantes: Sûreté Pour Soudage A L’Arc 1. Protegez-vous contre la secousse électrique: a. Les circuits à l’électrode et à la piéce sont sous tension quand la machine à souder est en marche.
v v Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Please Examine Carton and Equipment For Damage Immediately When this equipment is shipped, title passes to the purchaser upon receipt by the carrier.
vi vi TABLE OF CONTENTS Page Installation .......................................................................................................Section A Technical Specifications ........................................................................................A-1 Identify and Locate Components ...........................................................................A-2 Select Suitable Location ........................................................................................
A-1 A-1 INSTALLATION TECHNICAL SPECIFICATIONS – SP-135 PLUS INPUT – SINGLE PHASE ONLY Standard Voltage/Frequency Input Current 20 Amps @ Rated Output 25 Amps @ Maximum Output 15 Amps @ CSA Rated output 115V/60Hz RATED OUTPUT Duty Cycle 20% Duty Cycle – Rated DC Output Amps 90 Volts at Rated Amperes 18 OUTPUT Welding Current Range (Continuous) Rated DC Output: 25 – 135 Amps Maximum Open Circuit Voltage 28 Auxiliary Power N/A RECOMMENDED INPUT CABLE AND FUSE SIZES Output Mode RATED MAXIMUM Inpu
A-2 A-2 INSTALLATION FIGURE A.1 Read entire installation section before starting installation. 1 SAFETY PRECAUTIONS 2 WARNING ELECTRIC SHOCK can kill. • Only qualified personnel should perform this installation. • Only personnel that have read and understood the SP-135 PLUS Operating Manual should install and operate this equipment. 4 • Machine must be plugged into a receptacle which is grounded per any national, local or other applicable electrical codes.
A-3 A-3 INSTALLATION SELECT SUITABLE LOCATION Work Clamp Installation Locate the welder in a dry location where there is free circulation of clean air into the louvers in the back and out the front of the unit. A location that minimizes the amount of smoke and dirt drawn into the rear louvers reduces the chance of dirt accumulation that can block air passages and cause overheating. Attach the work clamp per the following: 1. Unplug the machine or turn the power switch to the “OFF” position. 2.
A-4 A-4 INSTALLATION 3. Route the cable under and around the back of the Wire Feed Gearbox (6). 4. For GMAW Only: Refer to Figure A.2. As delivered, the SP-135 PLUS is wired for positive polarity. This is the appropriate configuration for the Gas Metal Arc Welding (GMAW) process. To complete installation, use the provided wing nut to connect the work cable’s terminal lug to the negative (–) output terminal (5) located above the Wire Feed Gearbox (6). Make sure that both wing nuts are tight. 5.
A-5 INSTALLATION A-5 WARNING CYLINDER may explode if damaged. Keep cylinder upright and chained to support 2. With the cylinder securely installed, remove the cylinder cap. Stand to one side away from the outlet and open the cylinder valve very slightly for an instant. This blows away any dust or dirt which may have accumulated in the valve outlet. • Keep cylinder away from areas where it may be damaged. • Never lift welder with cylinder attached. • Never allow welding electrode to touch cylinder.
A-6 A-6 INSTALLATION CODE REQUIREMENTS FOR INPUT CONNECTIONS CAUTION Do not connect the SP-135 PLUS to an input power supply with a rated voltage that is greater than 125 volts. WARNING This welding machine must be connected to power source in accordance with applicable electrical codes. Do not remove the power cord ground prong.
B-1 OPERATION Read entire Operation section before operating the SP-135 PLUS. WARNING ELECTRIC SHOCK can kill. • Do not touch electrically live parts or electrode with skin or wet clothing. Insulate yourself from work and ground. • Always wear dry insulating gloves. FUMES AND GASES can be dangerous. • Keep your head out of fumes. • Use ventilation or exhaust to remove fumes from breathing zone. WELDING SPARKS can cause fire or explosion. • Keep flammable material away.
B-2 B-2 OPERATION GENERAL DESCRIPTION ● Reversible, dual groove drive roll. Drive roll will The SP-135 PLUS is a complete semiautomatic constant voltage DC arc welding machine. Included is a solid state controlled, single phase constant voltage transformer/ rectifier power source and a wire feeder for feeding solid steel electrode and cored electrode.
B-3 OPERATION B-3 WELDING OPERATIONS FIGURE B.1a SEQUENCE OF OPERATION WELDING AMP RANGE 25-125 Wire Loading Refer to Figure B.2 AND B3. 2 1 WELDING AMP RANGE 25-125 The machine power switch should be turned to the OFF (“O”) position before working inside the wire feed enclosure. 3 SP-135 Plus 4. Circuit Breaker – Protects machine from damage if maximum output is exceeded. Button will extend out when tripped (Manual reset). 5.
B-4 B-4 OPERATION FIGURE B.4 Wire Spindle Shaft To wire drive 4" Wire Spool 2 4 5 Wing Nut and Spacer 3 FIGURE B.3 Friction Brake Adjustment With wire spool installed on the spindle shaft and the wing nut loose, turn the spool by hand while slowly tightening the wing nut until a light drag is felt. Tighten the wing nut an additional 1/4 turn. Note: When properly adjusted, the brake should provide only enough drag to prevent overrun of the spool and excess slack in the wire.
B-5 OPERATION B-5 FIGURE B.5 FIGURE B.6 Gun Handle Contact Tip Gas Diffuser Contact Tip Wire Electrode Gas Nozzle 3/8"– 1/2"(10-13mm) Contact Tip to Work Distance(CTWD) Shielding Gas When using the GMAW process, a cylinder of shielding gas, must be obtained. Refer to the ACCESSORIES section for more information about selecting gas cylinders for use with the SP-135 PLUS. 1. For CO2, open the cylinder very slowly. For argonmixed gas, open cylinder valve slowly a fraction of a turn.
B-6 B-6 OPERATION 9. To stop welding, release the gun trigger and then pull the gun away from the work after the arc goes out. 10. When no more welding is to be done, close valve on gas cylinder (if used), momentarily operate gun trigger to release gas pressure, and turn off the SP-135 PLUS. Cleaning Tip And Nozzle Clean the contact tip and nozzle to avoid arc bridging between the nozzle and contact tip which can result in a shorted nozzle, poor welds and an overheated gun.
B-7 OPERATION OVERLOAD PROTECTION Output Overload The SP-135 PLUS is equipped with a circuit breaker which protects the machine from potential damage from excessive output current. The circuit breaker button will extend out when tripped. The circuit breaker must be manually reset. Thermal Protection The SP-135 PLUS duty cycle is exceeded a thermostat will shut off the output until the machine cools to a normal operating temperature. This is an automatic function and is self resetting.
B-8 APPLICATION CHART SP-135 PLUS B-8
C-1 ACCESSORIES OPTIONAL ACCESSORIES 1. K520 Utility Cart — Designed to transport the Lincoln family of small welders. Has provisions for mounting a single gas cylinder. Has front casters and large rear wheels. Handle height is easily adjustable. Bottom tray provided for tools and accessories. Easy assembly required; takes less than 15 minutes. 2. K586-1 Deluxe Adjustable Gas Regulator & Hose Kit Accommodates CO2 or mixed Gas Cylinders. C-1 4.
C-2 ACCESSORIES REPLACEMENT PARTS INNERSHIELD (FCAW) CONVERSION Several changes are needed to convert the unit for operation with the Innershield (FCAW) process. The K549-1 Innershield Kit includes all the necessary accessories for this conversion and are provided for this purpose. The following conversions should be made using the contents of this kit: 1. Change the output polarity to DC(-). See “Work Cable Installation” section for details. 2. Install proper drive roll for the wire size selected.
D-1 D-1 MAINTENANCE AFTER FEEDING 50# OF FLUX CORED WIRE OR 300# OF SOLID WIRE MAINTENANCE SAFETY PRECAUTIONS • Unplug machine or turn power switch to OFF – “O” position. Remove gun and cable from machine. WARNING • Remove gas nozzle and contact tip from gun. ELECTRIC SHOCK can kill. • Lay cable out straight - blow out gently into gun end with compressed air. Bend cable back and forth – blow out again – Repeat until clean.
D-2 D-2 MAINTENANCE GUN AND CABLE MAINTENANCE FOR MAGNUM™ 100L GUN Gun Cable Cleaning Clean cable liner after using approximately 300 lbs (136 kg) of solid wire or 50 lbs (23 kg) of flux-cored wire. Remove the cable from the wire feeder and lay it out straight on the floor. Remove the contact tip from the gun. Using low pressure air, gently blow out the cable liner from the gas diffuser end. 2. Replace worn contact tips as required. A variable or “hunting” arc is a typical symptom of a worn contact tip.
D-3 MAINTENANCE D-3 COMPONENT REPLACEMENT PROCEDURES CAUTION CHANGING THE CONTACT TIP 1. Unplug or turn power switch to Off “O” position. 2. Refer to Figure D.2. Remove the gas nozzle from the gun by unscrewing counter-clockwise. 3. Remove the existing contact tip from the gun by unscrewing counter-clockwise.
D-4 D-4 MAINTENANCE 1-1/4 (31.8 mm) Liner Trim Length Gas Diffuser Slotted Set Screw Brass Cable Connector Contact Tip (Threaded) Gas Nozzle or Gasless Nozzle (Threaded) Liner Assembly (Liner bushing to be seated tight against brass cable connector) FIGURE D.2 Liner trim length for gun with red trigger (Magnum™ 100L) CHANGING LINER 9. Screw the gas diffuser onto the end of the gun tube and securely tighten. NOTICE: The variation in cable lengths prevents the interchangeability of liners.
E-1 TROUBLESHOOTING E-1 HOW TO USE TROUBLESHOOTING GUIDE WARNING Service and Repair should only be performed by Lincoln Electric Factory Trained Personnel. Unauthorized repairs performed on this equipment may result in danger to the technician and machine operator and will invalidate your factory warranty. For your safety and to avoid Electrical Shock, please observe all safety notes and precautions detailed throughout this manual.
E-2 Observe Safety Guidelines detailed in the beginning of this manual. TROUBLESHOOTING GUIDE PROBLEMS (SYMPTOMS) E-2 TROUBLESHOOTING POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION OUTPUT PROBLEMS Major physical or electrical damage is evident. Contact your LOCAL LINCOLN AUTHORIZED FIELD SERVICE FACILITY. No wire feed, weld output or gas flow when gun trigger is pulled. Fan does NOT operate. 1. Make sure correct voltage is applied to the machine (115 vac). 2.
E-3 Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) E-3 TROUBLESHOOTING TROUBLESHOOTING GUIDE POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION FEEDING PROBLEMS No wire feed when gun trigger is pulled. Fan runs, gas flows and machine has correct open circuit voltage (28 vdc maximum) – weld output. 1. If the wire drive motor is running check to see if the correct wire is in the machine. 2.
E-4 Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) E-4 TROUBLESHOOTING TROUBLESHOOTING GUIDE POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION GAS FLOW PROBLEMS Low or no gas flow when gun trigger is pulled. Wire feed, weld output and fan operate normally. 1. Check gas supply, flow regulator and gas hoses. 2. Check gun connection to machine for obstruction or leaky seals.
531 31A 1 2 ( J1 ) SP-135 PLUS 32 L1 31 24 VAC AUX WDG. CIRCUIT BREAKER 5 206 6 31A 531 205 4 2 3 4 T1 201 N.A. N.D. 202 541 539 203 204 1 D3 D1 7 8 203 D4 10 N.B., N.D. 204 208 N.D. 211 9 203 203 213 D2 209 204 203 5 6 ( J2 ) A 208 207 204 209 R2 N.C. HIGH VOLTAGE can kill OUTPUT CHOKE 203 CONNECTOR CAVITY NUMBER 59,000 u f 40V C1 203 + 206 5K R1 WIRE SPEED 5K 205 204 A NOTES: N.A. DIODES D1 & D3 ARE MOUNTED ON THE OUTSIDE HEATSINK. N.B.
● Do not touch electrically live parts or WARNING Spanish AVISO DE PRECAUCION French ATTENTION German WARNUNG Portuguese ATENÇÃO ● Keep flammable materials away. ● Wear eye, ear and body protection. ● Mantenga el material combustible ● Protéjase los ojos, los oídos y el electrode with skin or wet clothing. ● Insulate yourself from work and ground. ● No toque las partes o los electrodos bajo carga con la piel o ropa mojada. ● Aislese del trabajo y de la tierra.
● Keep your head out of fumes. ● Use ventilation or exhaust to ● Turn power off before servicing. ● Do not operate with panel open or guards off. remove fumes from breathing zone. ● Los humos fuera de la zona de res- piración. ● Mantenga la cabeza fuera de los humos. Utilice ventilación o aspiración para gases. ● Gardez la tête à l’écart des fumées. ● Utilisez un ventilateur ou un aspira- ● Desconectar el cable de ali- mentación de poder de la máquina antes de iniciar cualquier servicio.
• World's Leader in Welding and Cutting Products • • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.