Instruction Manual

Chapter 10. Assembly Listing Tab Overview Report
10.2 CheckPoint™ User Manual IM8000
Field Description
Avg. Cycle Time (min) When a Weld Operator begins a sequence, they click the Start button in some
fashion (whether automatically at the end of the last one or manually). This
starts the Job Timer in Weld Sequencer. Once the Weld Operator completes
the sequence, the Job Timer stops. This provides you with a “Cycle Time”.
The Avg. Cycle Time column displays the average from all of the Weld
Sequence instances within this assembly.
Avg. Arc Time (min) CheckPointadds together all of the arc times from the welds within this
assembly and displays the average arc time in this column.
Avg. Arc Duty Cycle The Arc Duty Cycle is a calculation of how much time was spent in Arc On
time, out of the Cycle Time for the instances of the Weld Sequence in this
assembly. CheckPoint™ provides you with a percentage using the following
equation:
ܣݒ݃.ܦݑݐݕ ܥݕ݈ܿ݁ =
ܣݒ݃.ܣݎܿ ܶ݅݉݁
ܣݒ݃.ܥݕ݈ܿ݁ ܶ݅݉݁
Missing Welds Weld Sequencer knows how many welds the Weld Engineer expected for
each sequence. It also knows how many welds the Weld Operator
performed. CheckPoint™ displays the number of missing welds in this
column.
Extra Welds Weld Sequencer knows how many welds the Weld Engineer expected for
each sequence. It also knows how many welds the Weld Operator
performed. CheckPoint™ displays the number of extra welds in this column.
Welds Out of Limits This column displays the number of welds where limits were enabled, and the
weld went outside those limits.
If limits were not enabled for a weld, CheckPoint™ does not take that weld
into consideration for this column. If none of the welds in the assembly had
limits enabled, the Welds Out of Limits column is “0”.
For example, there were a total number of 1089 welds performed in the
assembly and 100 of those welds had limits enabled when they were
performed. Of those 100 welds, 15 were outside the limits set for the weld.
The Welds Out of Limits column would display 15.
Avg. WeldScore™ This column displays the average WeldScore™ for the welds in the assembly
where WeldScore™ was enabled. If WeldScore™ was not enabled for a weld,
it is not taken into consideration for this column. If none of the welds in the
assembly had WeldScore™ enabled, the Avg. WeldScore™ column is empty.
For example, there were 1089 welds in the assembly and 700 of those welds
had WeldScore™ enabled when they were performed. The Avg. WeldScore
column shows the average WeldScore™ for the 700 welds.
Avg. Deposition (lb) This column displays the amount of wire (in pounds or kilograms) that was
deposited for the welds made in this assembly.