Low or no gas flow when gun
trigger is pulled. Wire feed, weld
output and fan operate normally.
#"&&
(&
1. Check gas supply, flow regulator
and gas hoses.
2. Check gun connection to
machine for obstruction or leaky
seals.
%" !
"(%&"'"!
If all recommended possible areas
of misadjustment have been
checked and the problem persists,
<;A.0A F<B? 9<0.9 6;0<9;
BA5<?6G21 6291 &2?C602
.0696AF
&"*#%" &
#%" &
&, #'" &
Arc is unstable – Poor starting
#"&&
(&
1. Check for correct input voltage
to machine.
2. Check for proper electrode
polarity for process.
3. Check gun tip for wear or dam-
age and proper size – Replace.
4. Check for proper gas and flow
rate for process. (For MIG only.)
5. Check work cable for loose or
faulty connections.
6. Check gun for damage or
breaks.
7. Check for proper drive roll orien-
tation and alignment.
8. Check liner for proper size.
%" !
"(%&"'"!
If all recommended possible areas
of misadjustment have been
checked and the problem persists,