TROUBLESHOOTING & REPAIR
E-6
INVERTEC V250-S
Observe all Safety Guidelines detailed throughout this manual
OUTPUT PROBLEMS
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
The machine will not produce more
than 200 amps.
1. This may be normal operation. If
the output current exceeds 290
amps, an electronic protection
circuit will reduce the current to
less than 200 amps. The
machine will continue to produce
this low current until the
protection circuit is reset. Reset
occurs when the output load is
removed.
2. Check the input voltage and input
voltage reconnect procedures.
See Input Voltage Reconnect
Procedure.
3. Check for loose or faulty welding
cables.
If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized Field
Service Facility.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con-
tact your local authorized field service facility for technical troubleshooting assistance before you proceed.