Product Manual

A-1 A-1
INSTALLATION
Input Voltage/ 230Amps @ 300Amps @ 350Amps @ 75°C Copper Wire Fuse
Frequency (Hz) 29 Volts 32 Volts 34 Volts AWG (IEC) or
(100% Duty Cycle) (60% Duty Cycle)
(40% Duty Cycle)
Sizes (MM
2
)
Breaker Size
208/50*/60** 50A 76A 93A 6 (16 mm
2
) 100 A
230/50*/60 48A 64A 80A 6 (16 mm
2
)80 A
460/50*/60 25A 37A 45A 10 (6 mm
2
)50 A
575/50*/60 20A 29A 34A 12 (2.5 mm
2
)35 A
Wire the Welder to Dedicated circuit branch.
NOTE: Use #10 AWGGrounding Wire.
*For 50Hz operation: The duty Cycle Rating at 300 Amps is 40%. The duty cycle rating at 350 Amps is 30%.
**For 208V Input: The duty Cycle Rating at 300 Amps is 40%.
TECHNICAL SPECIFICATIONS – POWER MIG
®
350MP
INPUT – SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT
RECOMMENDED INPUT WIRE AND FUSE SIZES - SINGLE PHASE
Height Width Depth Weight
31.79 in 18.88 in 38.78 in 255 Ibs
808 mm 480 mm 985 mm 116 kg
PHYSICAL DIMENSIONS
Wire Speed 50 – 700 IPM (1.27 – 17.8 m/minute)
WIRE SPEED RANGE
Standard Voltage/Frequency
Input Current @ 230Amp Rated Output Input Current @ 300 Amp Rated Output
208/230/460/575/50/60 Hz 50/48/25/20 Amps 76/64/37/29 Amps
Input Voltage/Frequency Hz
Duty Cycle Amps Volts at Rated Amperes
208/60 40% 300 Amps 32 Volts
230/460/575/60 60% 300 Amps 32 Volts
208/230/460/575/60 100% 230 Amps 29 Volts
208/230/460/575/50 40% 300 Amps 32 Volts
208/230/460/575/50 100% 230 Amps 29 Volts
Welding
Current Range (Continuous) Maximum Open Circuit Voltage Welding Voltage Range
5 – 350 Amps 67 Volts 10-45 Volts
POWER MIG
®
350MP