Portable Generator User Manual
TROUBLESHOOTING & REPAIR
POWER-ARC 4000
F-20
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
CH1
0 volts
5 ms
20 volts
This is the typical AC output voltage
generated from a properly operating
machine. Note that each vertical
division represents 20 volts and that
each horizontal division represents 5
milliseconds in time. The mahine
was loaded with a resistance grid
bank.
Note: Scope probes connected at
machine output terminals.
SCOPE SETTINGS
Volts/Div....................20V/Div.
Horizontal Sweep ....5 ms/Div.
Coupling ............................DC
Trigger.........................Internal
MACHINE LOADED TO 125 AMPS AT 23 VAC
TYPICAL WELD OUTPUT WAVEFORM
MACHINE LOADED