DESIGNER IM649 User guide

3. Adjust the Start Control Parameters (Optional)
The start control parameters can be adjusted to define how the welding machine will respond
when the arc is struck.
To view the start control window, click on the button on the Waveform Editor screen.
Adjust the start control parameters to accommodate your welding application and per the
following parameter descriptions.
B-10 Appendix B
STT WAVE SHAPING PRINCIPLES
WAVE DESIGNER
STRIKE
PEAK I
STRIKE
TIME
START TIME
ARC
STRIKES
OPEN
CIRCUIT
VOLTS
AVERAGE
START
AMPS
@
START
VOLTS
27850058
Start Control - STT
STT Start Control
For Wire Feed Speed
Stage 1: Wire Run In
Open Circuit Volt
Stage 2: Striking Pulse
Strike Peak I
Strike Time
Strike |
Stage 3: Molten Ball Formation
Start Volt
Start Time
90
42.00
750
1.0
23.00
700
20.0
STRIKE I
Open circuit voltage: Sets the power source output voltage for the torch idle condition (the
welding machine is on, but not welding).
Strike time: Adjust this parameter to set the duration of peak current for the arc-strike current
spike.
Strike Peak I & Strike I: Adjust these parameters to set the peak current level for the arc-strike
current spike.
The Strike Peak I is set to some level (e.g. 50 amps) higher than the Strike I to improve current
step responsiveness. In other words, the actual current has a tendency of lagging behind in rapid
stepping of commanded current. A higher initial Strike Peak I is designed to overcome this
problem.
Starting volts: Adjust this parameter to set the gun voltage to be maintained during the arc
starting routine.
Starting time: Adjust this parameter to set the duration of the arc starting routine.