Low Profile Single Belt Conveyorized Oven Specification Sheet

Global
1111 North Hadley Road
P.O. Box 1229
Fort Wayne, Indiana 46801-1229
Tel 1.260.459.8200
Fax 1.260.436.0735
E mail info@lincolnfp.com
web www.lincolnfp.com
©2007 Lincoln Foodservice Products, Inc.
Printed in the U.S.A.
1256-2.5K-04/07-SP
Capacity Estimates | Pies Per Hour:
BAKE TIME
Pie Size 3 min. 3½ min. 4 min. 4½ min. 5 min. 5½ min. 6 min. 6½ min. 7 min.
12” (30 cm) 182 155 135 120 108 99 90 84 78
14” (36 cm) 115 99 87 88 69 63 58 53 50
16” (41 cm) 101 87 76 67 61 55 51 47 44
Ventilation Requirements:
Ventilation is required. Local codes prevail. These are the “authority having jurisdiction as stated by the
National Fire Protection Association, Inc., in NFPA 96-1994. Estimates of CFM requirements can vary from
2400 to as high as 6000 CFM exhaust. In all cases the ambient temperature around the oven must not
exceed 95°F (35°C) when the oven is operating. This information is shown as a guideline for ventilating
the Impinger
®
1600 Ovens.
18-24”
(457 mm -
610mm)
8”
(203 mm)
CAPTURE AREA CAPTURE AREA
CAPTURE VELOCITY 50 FPM
CAPTURE
VELOCITY
50 FPM
78”
(1981 mm)
94” (2388 mm)
8”
(203 mm)
6”
(153 mm)
6”
(153 mm)
70” (1778 mm)
1. Dimensions shown are for ovens without long extension shelves. The outside end of the conveyor
frame must be a minimum of eight (8) inches (203 mm) inside the canopy as shown.
2. The capture velocity across the lower edge of the canopy is to be 50 FPM at sides and front.
3. Use lters at rear exhaust area of the hood, as shown. Do not just put an opening into a 4 sided canopy.
4. The ovens are to be centered in the canopy space left-to-right and front-to-back if possible.
5. A six (6) inch space at rear of oven is recommended for utilities.
6. Use of a Type I or Type II application and overall nal installation is determined per local codes.
7. Recommended 2400-3000 CFM exhaust, typical, or higher per local codes; as a guideline to obtain
adequate capture velocity.
8. Recommended 80% of make-up air provided outside of the canopy through perforated metal dif-
fusers directed straight down... not at the oven; located at front , side or both.
9. Room air diusers must not be directed onto the oven and should be positioned a minimum of
three (3) feet from the perimeter of the hood to keep airow from aecting the oven.
NOTE: Specications subject to change without notication.