Operating Instructions

6
Status LEDs
The status LED supports the operator during the
charging process, commissioning and data
transmission as follows:
LED is off: The unit is active in the measurement
or the unit is deactivated due to an empty
battery.
LED flashes red (1 time per second): The battery
is being charged and has a charge level below
80%.
LED flashes red (3 times per second): The
battery is being charged and has a charge level
below 80%. Measurement data is available on
the device.
LED flashes green: The battery is charged and
has a charge level above 80%.
LED is constantly green: the battery is fully
charged and the internal time is set.
LED flashes alternately between green and red:
data is being transmitted to the gateway
Activate measurement
The units activate the measurement automatically
when the following criteria are met:
Battery has enough capacity
The internal time is set
When commissioning, it is important that the battery is
fully charged. This is the only way to achieve the
maximum runtime.
The gateway automatically sets the internal time of the
activity tracker as soon as the activity tracker is within a
range of 10m around the gateway.
If the activity tracker is brand new or has been completely discharged, e.g. after a long period of
storage, the time must be reset.