Operating Instructions

Operating devices and display elements
3
Operating Instructions - X EN - 01/2020
15
Power supply
The LED indicates the operating status of the
Truck Unit:
LED flashes green:
Truck Unit is ready for operation.
LED flashes red:
The Truck Unit has registered an error. The
Truck Unit is in programming mode.
LED lights up red:
The Truck Unit has registered an error. The
Truck Unit is in programming mode.
Number of persons in the signaling
zone
The display indicates the number of people in
the signaling zone. The display ranges from 0
- 9 people. If the display flashes, there are more
than nine (9) people in the signaling zone.
Signaling zones
The LEDs for the signaling zones indicate
whether there are pedestrians in one of the
signaling zones. If there are pedestrians with
distance beeper in the signaling zone, the
LEDs flash in a constant rhythm.
The following operating states are possible:
Three LEDs flash red:
A person is in the extended area. The LEDs
indicate the direction from which the person
is approaching.
Three LEDs flash orange:
An industrial truck with a truck-to-truck
sensor or a communication unit is located in
the extended area. The LEDs indicate the
direction from which the industrial truck is ap-
proaching.
Multiple LEDs flash red:
There are several people in the extended
area. The LEDs indicate the direction from
which the people are approaching.
This function must be switched on in the
configurator.
NOTICE
LSG_0031