Operating Instructions

Operation 4
Operating Instructions - X EN - 01/2020
33
Installing a Static Unit
The Static Unit is mounted at points
that are difficult to see and thus
allows the early detection of
approaching industrial trucks.
Position the Static Unit so that the
LED display
is easy to see.
Install the Static Unit between a
height of 2m (78inch) but not higher
than 7m (275inch) in order to
guarantee optimal radio coverage.
Installation via magnet
The Static Unit can be mounted to
metal surfaces using a magnet.
1. Mount a self-adhesive magnet
with the sticky side on the rear of
the housing.
2. Attach the Static Unit in the
intended location.
3. Connect the Static Unit to the
mains connection.
The Static Unit starts and the
operating status LED flashes green.
Installation via screw joint
To expose the fixing points, open the
hous ing panels(1) at the sides.
1. Ensure it is level
2. Mark the four fixing points on
the ground.
3. Drill mounting holes and then
insert dowels if these are
required.
4. Mount the Static Unit with four
screws and close the housing
panels.
5. Connect the Static Unit to the
Mains connection.
The Static Unit starts and the
operating status LED flashes green.
NOTICE
1
2