User guide

 




87
Host conguration
This page provides the opportunity to congure various details for each of the
host systems that may be connected to the MC5-IP via one or more KVM switch
units. There are 128 entries, each of which can be congured with a name,
the permitted users, the hot key combinations required to switch to it and, if
required, appropriate power control commands.
To create a new host entry
1 Click one of the host entries to reveal a Host conguration dialog.
Name
Enter the name that will be displayed in the viewer window when you
click the Host button.
Users
Select the users that will be permitted to connect to this host. Either
enter
*
to allow all users or a list of users separated by commas (e.g.
admin, nigel, andy, steve).
KVM Port
Declare the Port Direct address that will link with the required host
system. See Port Direct for details.
A list of valid hotkey codes are given in Appendix 8.
Power On
Enter the code required to make an attached power control unit apply
power to the selected host. See Power switching conguration for
details.
Power Off
Enter the code required to make an attached power control unit remove
power from the selected host. See Power switching conguration for
details.
2 Enter the required information in each eld.
3 Click the OK button.
To get here
1 Using VNC viewer or a browser, log on as the ‘admin’ user.
2 Click the ‘Congure’ button in the top right corner.
3 Click the ‘Host conguration’ option.
Add entry for unrecognised host
When selected, any systems visited that are not specied in the Hosts list, will
be added to the list. Use with care when visiting complex cascaded systems.
Erase Host Conguration
Removes all hosts from the list.