Safety Considerations
The LTM4611 modules do not provide galvanic isolation
from V
IN
to V
OUT
. There is no internal fuse. If required,
a slow blow fuse with a rating twice the maximum input
current needs to be provided to protect each unit from
catastrophic failure. The device does support overvoltage
protection and overcurrent protection.
Layout Checklist/Example
The high integration of LTM4611 makes the PCB board
layout very simple and easy. However, to optimize its
electrical and thermal performance, some layout consid-
erations are still necessary.
Use large PCB copper areas for high current paths,
including V
IN
, GND and V
OUT
. It helps to minimize the
PCB conduction loss and thermal stress.
Place high frequency ceramic input and output capaci-
tors next to the V
IN
, GND and V
OUT
pins to minimize
high frequency noise.
Place a dedicated power ground layer underneath the
unit.
To minimize the via conduction loss and reduce module
thermal stress, use multiple vias for interconnection
between top layer and other power layers.
Do not put vias directly on the pad, unless they are
capped or plated over.
Use a separated SGND ground copper area for com-
ponents connected to signal pins. Connect the SGND
to GND underneath the unit.
For parallel modules, tie the respective COMP, V
FB
,
V
OUT_LCL
, TRACK/SS and RUN pins together. Use an
internal layer to closely connect these pins together.
Figure 17 gives a good example of the recommended
layout. Figures 18 and 19 show schematics of the
LTM4611 devices operating in parallel.
To facilitate stufng verication, test and debug activi-
ties, consider routing control signals of the LTM4611
with short traces to localized test points, test pads or
test vias–as PCB layout space permits. Both in-house
and contract manufacturers enjoy gaining electrical
access to all non low impedance (>10Ω) pins of an
IC or µModule device to improve in-circuit test (ICT)
coverage.