Note 1: Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect device
reliability and lifetime.
Note 2: The LT8582E is guaranteed to meet performance specifications
from 0°C to 125°C junction temperature. Specifications over the
–40°C to 125°C operating temperature range are assured by design,
characterization and correlation with statistical process controls. The
LT8582I is guaranteed over the full –40°C to 125°C operating junction
temperature range.
PARAMETER CONDITIONS MIN TYP MAX UNITS
SHDN Pin Bias Current V
SHDN
= 3V
V
SHDN
= 1.3V
V
SHDN
= 0V
10.1
45
12.1
0
65
14.1
0.1
µA
µA
µA
CLKOUT Output Voltage High 1mA out of CLKOUT Pin 1.9 2.1 2.3 V
CLKOUT Output Voltage Low 1mA into CLKOUT Pin 30 200 mV
CLKOUT1 Duty Cycle All T
J
50 %
CLKOUT2 Duty Cycle T
J
= –40°C
T
J
= 25°C
T
J
= 125°C
22.5
42
72
%
%
%
CLKOUT Rise Time C
CLKOUT
= 120pF 25 ns
CLKOUT Fall Time C
CLKOUT
= 120pF 15 ns
GATE Pull-Down Current V
GATE
= 3V
V
GATE
= 20V
l
l
0.8
0.8
1
1
1.2
1.2
mA
mA
GATE Leakage Current V
GATE
= 50V, GATE Off 0.01 1 µA
PG Threshold for Positive Feedback Voltage V
FBX
Rising 1.09 1.15 1.20 V
PG Threshold for Negative Feedback Voltage V
FBX
Falling 20 65 120 mV
PG Hysteresis for Feedback Voltage 4mV
PG Output Voltage Low 100µA into PG Pin, V
FBX
= 1V
l
70 150 mV
PG Leakage Current V
PG
= 40V, V
FBX
= 1.204V 0.01 1 µA
ELECTRICAL CHARACTERISTICS
The l denotes the specifications which apply over the full operating
temperature range, otherwise specifications are at T
A
= 25°C. V
IN
= 5V, V
SHDN
= V
IN
, unless otherwise noted (Note 2). Specifications
are identical for both channels unless noted otherwise.
Note 3: Current limit guaranteed by design and/or correlation to static test.
Note 4: This IC includes overtemperature protection that is intended
to protect the device during momentary overload conditions. Junction
temperature will exceed 125°C when overtemperature protection is active.
Continuous operation over the specified maximum operating junction
temperature may impair device reliability.
Note 5: Do not apply a positive or negative voltage or current source to
CLKOUT, otherwise permanent damage may occur.