FuncTion Tables
Table 5. RS485 Driver Mode for a Given Port (485/232 = 1, TE485 = 0)
DXEN DY CONDITIONS Y Z
0 X No Fault 125kΩ 125kΩ
1 0 No Fault 0 1
1 1 No Fault 1 0
X X Thermal Fault 125kΩ 125kΩ
Table 6. RS485 Receiver Mode for a Given Port (485/232 = 1, LB = 0)
RXEN A–B (NOTE 5) CONDITIONS RA
1 X No Fault Hi-Z
0 < –200mV No Fault 0
0 > 200mV No Fault 1
0 Inputs Open or Shorted Together (DC) No Fault 1
X X Thermal Fault Hi-Z
Table 7. RS485 Termination for a Given Port (485/232 = 1)
TE485 DZ H/F, LB CONDITIONS R(A TO B) R(Y TO Z)
0 X X No Fault Hi-Z Hi-Z
1 0 X No Fault 120Ω Hi-Z
1 1 X No Fault 120Ω 120Ω
X X X Thermal Fault Hi-Z Hi-Z
Table 8. RS485 Duplex Control for Given Port (485/232 = 1)
H/F RS485 DRIVER OUTPUTS RS485 RECEIVER INPUTS
0 Y, Z A, B
1 Y, Z Y, Z
Table 9. Loopback Functions for a Given Port
LB RXEN TRANSCEIVER MODE
0 X Not Loopback
1 1 Not Loopback
1 0 Loopback (RA = DY, RB = DZ)
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.