Owner's Manual

SPECIFICATIONS:
MECHANICAL:
XT CASE DIMENSIONS:
2.75”w x 4.50”h x 1.50”d
PROGRAMMER CASE DEMENSIONS:
2.75”w x 4.50”h x 2.50”d
ELECTRICAL:
VOLTAGE:
12-24 Volts AC/DC (selected by jumper)
CURRENT:
@12-24 Volts AC/DC- 20ma typical-150 max with all relays
energized
OUTPUTS:
Main relay: 8 Amp, Form-C @ 24volts-10 AMP surge
Relays 2, 3, & 4 are Form C relays-1 AMP MAXIMUM
212xt Wiring Diagrams and Specifications
P1
P4
P3
P2
RELAY
+
NO
SW1
NC C
P1-REX INPUT
P2-RELAY 2
P3-RELAY 3
P4-RELAY 4
P5-VOLTAGE SELECTOR
SW1-PROGRAMMING SWITCH
P5*
*P5 is the Voltage Selector. With the jumper in position one, 12-15vdc only operation is
selected. With the jumper in position two 15-24vdc/12-24vac operation is selected.
Packing Checklist:
Xtreme™ Keypad
212 XT Programming Controller
Four Conductor Wire Harness (1)
Three Conductor Wire Harness (4)
Slotted Screws (4)
Plastic Anchors (4)
Machine Screws (2)
5/64 Allen Head Wrench (1)
Tech Supp. With Warranty card
Command & Control Features and Programming Guide
TM
INTERNATIONAL
ELECTRONICS, INC
INTERNATIONAL ELECTRONICS, INC.
427TURNPIKE STREET, CANTON,MA 02021 U.S.A.
800-343-9502, 617-821-5566 (FAX)617-821-4443
P5*
Position
1
12-15VDC
12-24VAC
6061170 REV 1.01
Voltage Selection Settings
15-24VDC
ENVIRONMENTAL:
TEMPERATURE:
-20°F TO 130°F (-28°C TO 54°C)
1
2
3
4 5 6
7 8
9
*
0
#
( White / Yellow )
( White / Black )
( Red )
( Black )
Wire Xtreme Pad
to Appropriate color
wires on Programmer
(Red to Red, etc.)
Visit our website for Access Control & Glassbreak information,
New Products, Specifications, Applications, Seminars, and Partners
@ WWW.IEIB.COM