Owner's Manual
6064440 Rev 3.1 1
DOOR♦♦GARD SELF-CONTAINED ACCESS
CONTROL SYSTEMS
234 Wiring Diagrams and Specifications
TECHNICAL NOTES
• NEW- HI-CO & LOW-CO CAPABILITY: This card reader is capable of
reading most High and Low Coercivity Magnetic Stripe cards (Including 300,
2750 & 4000 Oersted). Place the P3 jumper cap ON both pins located on the
card reader circuit board to set it for HI-CO cards. It should also read most
LOW-CO cards reliably. If only LOW-CO cards are being used, place the
jumper cap on one pin.
• To avoid ESD (electro-static discharge) from interfering with the operation of
the Door♦Gard, ground the negative terminal of the keypad to earth ground. If
the power supply cannot be grounded, then ground the case.
• If a door position switch is not used, you must short the white and white/orange
wires on P6 for REX to work.
• The bi-color LED provided with this Door♦Gard lights red when the Main
Relay is de-energized and green when the Main Relay is energized.
• When mounting this unit outside, apply silicone to any non-factory drilled holes
in the case. This helps prevent warm air from condensing on the circuit board.
• For use in extreme weather conditions, please consult the factory for additional
methods of protecting your Door♦Gard from the environment.
• To speed up installation, holes have been spotted on the inside back of the
housing for mounting to a wall, single or double-gang electrical box.
• Holes have been spotted on inside front of the housing for the addition of extra
LED’s (not included).
SPECIFICATIONS
Case Dimensions: 4.50”w x 4.50”h x 1.55”d
Operating Voltage: 12 -24V AC/DC (No Jumper)
Max Current Draw: 12VDC: 45mA
24VDC: 55mA
12VAC: 77mA
24VAC: 98mA
Main Relay Contacts (K1): 2 Amp @ 12-24VAC/DC
Auxiliary Relays Contacts (K2, K3, K4): 1 Amp @ 12-24VAC/DC
Environment: Indoor or Outdoor
Temperature: -31°F to 151°F (-35°C to 66°C)