Owner's Manual

Document #: 6062130 Rev 2.0
Control Panel Interface Series
The Partitioner
262B Door-Gard Self-Contained Two Zone Control
16 User Codes (arm/disarm or arm only)
Keypad Programmable
Non-Volatile EEPROM Memory
Programmable Entry/Exit Delay Periods
Form-C 1 Amp Alarm Relay
Built-In Siren Driver
Pre-Alarm Sounder
Perimeter Zone
Interior Zone
At Home Arming
Unique Touch Shunt Mode
Programmable Alarm Recycle Time
Programmable Panic
Loop Status and Armed LED’s
Contemporary Plastic Housing
Alarm Memory by Zone
Keypad Backlighting
System Defaults
The Partitioner is designed for easy installation in a minimum
amount of time. The following default values are factory
programmed:
Exit Delay 60 seconds
Perimeter Entry Delay (Zone 1) 30 seconds
Interior Entry Delay (Zone 2) 30 seconds
Alarm Recycle Time 3 minutes
Panic Input Off
Audible Key Press On
Relay State (when not in alarm) Energized (supervised)
Upon alarm condition, the relay changes state and the siren
driver output energizes.
If it is necessary to change any of these default values, please
refer to the Programming Options Chart after you are familiar
with the programming section.
Memory
Non-Volatile EEPROM memory means programmed
information won’t be lost if power is removed.
Programming
All programming is accomplished entirely from the front of
the keypad. LED guidance makes programming easy and
changing codes takes a matter of seconds for an authorized
user.
Codes
The Partitioner allows up to 16 valid individual user codes.
Codes can be from 1 to 6 digits in length and digits can be
repeated.
Arming Interlock
The Partitioner cannot be armed if a zone is unsafe (open).
The sounder signals three short beeps to indicate this
condition.
At Home Arming
When At Home Arming is activated, the interior zone (zone 2)
is automatically shunted. At Home Arming is activated by
pressing the # key within 5 seconds of arming. At Home
Arming is indicated by both red and green LED’s lighting
when the systems are armed.
Touch Shunt
The perimeter zone (zone 1) can be shunted by pressing and
holding any key while the Partitioner is armed. If the key is
released while the perimeter zone is violated, the Partitioner
triggers the alarm instantly, bypassing the entry delay.
Alarm Memory/Loop Status
Pressing and holding the 1 or 2 keys for 2 seconds indicates
the current status and memory of the corresponding zone (1 =
zone 1 and 2 = zone 2). The sounder beeps twice to
acknowledge a key hold down. The red LED lights if an
alarm has occurred on that zone. The green LED lights if the
zone is closed. Alarm memory is cleared by pressing and
holding the 0 until the sounder beeps twice. Alarm memory
can only be indicated when the Partitioner is disarmed.
Panic
The Partitioner has the ability to trigger an instant alarm when
the * and # keys are pressed simultaneously. Panic operates
regardless of whether or not the Partitioner is armed. Panic
triggers both the alarm and siren driver. This feature is
defaulted to off from the factory, but can be turned on through
the Programming Options Chart. Panic is reset by entering a
valid arm/disarm code.
The Partitioner 262B Door-Gard is a self-
contained two-zone control system. A Form-C
alarm relay ties in easily to any standard
alarm zone creating an independent sub-
system. The Partitioner is the perfect choice
for office suites, apartments, strip malls or
any place individual zone control is desired.