Owner's Manual
Document #: 6062130 Rev 2.0
Notes:
If the master code is forgotten or does not work,
momentarily press the SW1 programming
switch to enter program mode. SW1 is located
on the front of the circuit board below the S1
keypad connector and can be accessed by
removing the keypad from the front. DO NOT
REMOVE THE KEYPAD RIBBON CABLE.
If the red LED turns on during programming
mode, a programming error has occurred.
Press * to clear the error and continue
programming.
Getting Started
Testing the System
1. Close perimeter loop (zone 1).
2. Close interior loop (zone 2).
3. Connect the positive (+) lead of your 12
Volt DC power supply to the terminal
strip (TS1) +V input on the Partitioner.
4. Connect the negative (-) lead of your 12
Volt DC power supply to the terminal
strip (TS1) -V input on the Partitioner.
5. Turn on your power supply. The
Partitioner flashes all LED’s for 2
seconds, then enter normal operating
mode.
6. Enter Self-Test Mode by pressing
7890#123456*. The LED’s light
sequentially and the keypad is now in
Self-Test Mode.
7. Open each loop one at a time. The
sounder sounds continuously as long as
loop is open. Close each loop after
testing.
8. Once you’ve verified proper operation,
press any key to exit Self-Test Mode.
Note: You can program the keypad in
your shop or at the installation site.
Programmed information is stored in non-
volatile memory and won’t be lost if
power is removed.
LED Indications
Green LED: Loop Status
On = Loops closed (safe to arm)
Off = Loop(s) open (won’t arm)
Red LED: Armed/Alarm Memory
On = System Armed
Off = System Disarmed
Flashing = System is (or was) in alarm
Red and Green LED’s Together
On = System Armed (At Home Mode)
Yellow LED
Rapid Flash = Entry Delay Warning
Note: The yellow Led is also used during
program mode.
Programming User Codes
1
Operation Yellow LED
1. Enter Programming Mode
Press 99# (master code)*
2
Flashes Slow
2. Change Master Code
3
Press 1# (enter master code)* Flashes Fast
Press (enter master code)* Flashes Slow
3. Add/Change Second Code
Press 2# (enter user code)* Flashes Fast
Press (enter user code)* Flashes Slow
4. Add Change Third Code
Press 3# (enter user code)* Flashes Fast
Press (enter user code)* Flashes Slow
5. You can add up to 16 codes in this fashion.
6. Exit Programming Mode
Press * Off
1
Codes can be 1 to 6 digits in length.
2
The master code is defaulted to 1234 and allows
access to programming mode.
3
The master code is always user #1.