Owner's Manual

Document #: 6062130 Rev 2.0
Programming Options Chart
Operation Key Sequence
1. Enter Programming Mode 99 # (master code) *
2. Add/Change User Code (user location) # (enter code) * (repeat code) *
3. Delete User Code (user location) # * *
4. Enter Arm Only Code 0 # (user location) # (enter code) * (repeat code)*
5. Set Entry Delays
(1 to 90 seconds or 0 for instant)
Perimeter Zone 80 # (time) # 0 # * *
Interior Zone 81 # (time) # 0 # * *
6. Set Exit Delay 82 # (time) # 0 # **
(1 to 90 seconds or 0 for instant)
7. Set Alarm Recycle Time 84 # (time) # 0 # * *
(Enter 1 to 90 for 10 to 900 seconds)
8. Turn Audible Keypress Feedback On 30 # 1 # 1 # * *
9. Turn Audible Keypress Feedback Off 30 # 1 # 0 # * *
10. Relay Energized Upon Power-Up (supervised) 30 # 2 # 1 # * *
11. Relay De-energized Upon Power-Up 30 # 2 # 0 # * *
12. Turn Panic Feature On 30 # 3 # 1 # * *
12. Turn Panic Feature Off 30 # 3 # 0 # * *
13. Erase Keypad Memory/Reset Defaults 46 # 00000 # 00000 # * *
14. Exit Programming Mode *
Specifications
Operation Voltage: 10.5 16 VDC
Ripple: 0.5 Volts
p-p
Alarm Relay: 1 Amp Form-C
Power Consumption: 32mA @ 10.5VDC
50mA @ 16VDC
Avg. 800mA w/ siren
1500mA peak
Siren Driver: 8 (ohm) speaker sweep
9 Watts avg. at 12 Volts
18 Watts peak at 12 Volts
Size: 2.75W x 4.5”H x 1.5”D
Loops: 300 (ohms) maximum
Loop Response: 300 milliseconds typical
Temperature: -20°F to 130°F (-28°C to 54°C)