PRINTER’S INSTRUCTIONS: INSTR,INSTL,AE-2000 - LINEAR P/N: 220231 B - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” - SCALE: 1-1 - FOLDING: ALBUM-FOLD - BINDING: SADDLE-STITCH AE-2000 Telephone Entry & Access Control System Installation Instructions USA & Canada (800) 421-1587 & (800) 392-0123 (760) 438-7000 - Toll Free FAX (800) 468-1340 www.linearcorp.
Contents Introduction ........................................................................... 2 Operation............................................................................... 2 Hardware Features ................................................................ 3 Software Highlights ............................................................... 3 Feature Overview ................................................................... 3 Accessory Overview.............................................
Hardware Features Feature Overview ✓ BUILT-IN RADIO RECEIVER Variable gain, high-sensitivity receiver for wireless transmitters ✓ FOUR FORM “C” (N.O. & N.
Accessory Overview PBUS Accessories Several compatible accessories are available to connect to the AE-2000’s three 6-wire communications “PBUS” inputs. Up to six PBUS accessories can be used with each AE-2000 unit.
Component Locations DISPLAY OPTIONAL CAMERA MICROPHONE LEFT CABINET LOCK FUNCTION BUTTONS RIGHT CABINET LOCK OPTIONAL POSTAL LOCK SPEAKER KEYPAD INSTALLATION NOTE: FOR EASY WIRING, THE UNIT'S TERMINAL BLOCKS CAN BE UN-PLUGGED FROM THE CIRCUIT BOARD TAMPER SWITCH CAMERA CONNECTOR (HIDDEN) PROMPT SPEECH VOLUME ANTENNA CPU/INTERFACE RESIDENT'S VOICE ADJUSTMENT CONNECTOR CONNECTOR VOLUME TAMPER OPTIONAL RECEIVER ADJUSTMENT SWITCH RANGE KNOB CONNECTOR CAMERA TAMPER MAGNET VIDEO CONNECTOR WIEGAND INPUT T
Wiring Diagram THIS WIRING EXAMPLE SHOWS: DOOR ACCESS WITH A DOOR STRIKE ON RELAY CHANNEL "A" DOOR ACCESS WITH A MAGNETIC LOCK ON RELAY CHANNEL "B" GATE ACCESS WITH A GATE OPERATOR ON RELAY CHANNEL "C" (YOUR INSTALLATION MAY VARY) ELECTRIC DOOR STRIKE AE-2000 PBUS DEVICE PWR GND DAT1 DAT0 DVAL PCLK PBUS DEVICE PBUS DEVICE AE-1000 AE-2000 AM-3 PWR GND DAT1 DAT0 DVAL PCLK PWR GND DAT1 DAT0 DVAL PCLK AE-1000 AE-2000 AM-3 AE-1000 AE-2000 AM-3 READER A TERMINALS LED2 HOLD LED1 DAT 1 DAT 0 GND PWR R
Important Mounting Requirements The AE-2000 Telephone Entry System can be installed for public or private use. The mounting requirements will vary depending on the installation. Review the following information before beginning the installation. Mounting Environment Consider the environmental factors at the desired mounting location. The AE-2000 is designed for direct outdoor installations, however, it is preferable to protect the unit from extreme exposure to sun, driving rain, or snow whenever possible.
Entry System Mounting The AE-2000 cabinet is designed to be mounted three ways: • The unit can be mounted directly to a wall or flat surface. • The unit can be mounted recessed into the wall. • The unit can be mounted on a standard gooseneck pedestal. Choose a well lit location near the controlled opening. Wiring access for power, telephone, earth ground, control output must be available to the mounting location.
Entry System Mounting (Continued) Recessed Mounting The cabinet can be mounted recessed using the accessory trim-ring (P/N ACP00914). The trim-ring mounts in the wall and the cabinet attaches to the trim-ring. 1. Identify the location of any studs in the wall. 2. Cut a 15-½” wide by 19” high rectangular hole between studs at the mounting location. 3. Install any additional mounting material required to provide surfaces inside the wall 15-½” apart for attaching the trim-ring. 4.
Relay Output Wiring TYPICAL DOOR STRIKE HOOKUP Any of the four relay outputs channels (A-D) can be used to control access devices on doors or gates. RELAY TERMINALS N.C. COM N.O. DS GND RTE ELECTRIC DOOR STRIKE Door or Pedestrian Gate Control 1. Install a low voltage electric door strike or magnetic lock as a locking device for the door or pedestrian gate. 2. Install the power supply or transformer for the locking device. DO NOT POWER THE AE-2000 FROM THIS POWER SUPPLY. 3.
Power, Battery, & Ground Wiring Power Wiring ✦ NOTE: DO NOT APPLY POWER UNTIL THE INSTALLATION IS COMPLETE. TURN MASTER POWER SWITCH OFF BEFORE WIRING. 1. Route two wires between the AE-2000 and the power transformer. • For power wire runs up to 75 feet, use 18 AWG, THHN 600-volt insulated wire. • For power wire runs up to 150 feet, use 16 AWG, THHN 600-volt insulated wire. 2. Connect the wires to the transformer. Connect the other end of the wires to the AE-2000 AC1 & AC2 terminals.
Telephone Wiring For telephone entry and programming, the AE-2000 connects to a standard telephone line. TELEPHONE TERMINALS Important Telephone Wiring Tips EARTH TIP RING • DO NOT ROUTE TELEPHONE AND AC WIRING INSIDE THE SAME CONDUIT. Route all telephone wires inside a dedicated conduit that is at least six inches away from any AC line wiring.
Optional Postal Lock A postal lock can be installed in the AE-2000 Entry System to provide keyed access for the postal service. The AE-2000 case is designed to accept a U.S. Postal Service postal lock. When the postal lock is engaged, the programmed output relay will activate. 2 REMOVE PLATE 1 REMOVE LOCKNUTS Postal Lock Installation 1. After opening the cabinet, re-lock the left cabinet lock to provide clearance to remove the postal lock switch plate. 2.
PBUS Accessories Six accessories (keypads, proximity readers, remote receivers) can be connected to the AE-2000’s three PBUS input/output ports. A typical application for a remote keypad would be to control a second door or gate. Linear’s PBUS devices compatible with the AE-2000 are: • AM-RRR Remote Radio Receiver • AM-RPR Radio Proximity Receiver • AM-KP Exterior Keypad • AM-KPI Interior Keypad • AM-CRI Card Reader Interface 1. Mount and install the accessory as described in its installation instructions.
Optional Network Connection Linear’s AE-1000, AE-2000, & AM-3 Access Control Systems can be connected together in a network. A network will allow sharing programming and user information between the systems. Network wiring conforms to 3-wire RS-485 electrical specifications. Units connected in the network can be wired using one unit as a “hub” or by wiring from one unit to the next in “daisy-chain” fashion. See the figures for wiring options. • Use Belden 9925 or Carol C0600 shielded cable or equivalent.
System Adjustments The factory settings are sufficient for most installations. The system can be adjusted to customize the installation. SYSTEM VOLUME ADJUSTMENT LESS MORE System Volume Adjustment The sound level of the synthesized voice and key beep can be adjusted. 1. Locate the SYSTEM VOLUME adjustment on the CPU circuit board. 2. Press keys on the keypad while adjusting the control until the sound is at the desired level. Turn the adjustment clockwise for more volume, counterclockwise for less volume.
Internal Controls On-board Pushbuttons Seven pushbuttons are on the main circuit board. Refer to the figure for the location of each pushbutton. • “UP” BUTTON adds one to the value on the STATUS/PROGRAM display. • “DOWN” BUTTON subtracts one from value on the STATUS/PROGRAM display. • • • • • STATUS/PROGRAM DISPLAY "UP" BUTTON "DOWN" BUTTON "ENTER" BUTTON RELAY “A” LATCH press to latch relay “A”, press again to un-latch.
Visitor Access with a Resident Call AE-2000 Operation Resident Access with an Entry Code PRESS THE KEY BELOW THE OR REPEATEDLY TO SCROLL THROUGH THE RESIDENT'S NAMES - OR - KEY IN AN ENTRY CODE AT THE SYSTEM KEYPAD OR ENTER A CODE AT A REMOTE KEYPAD TO SCROLL THROUGH FASTER, PRESS AND HOLD THE KEY BELOW OR THEN RELEASE THE KEY WHEN THE DESIRED LETTER IS UNDERLINED IF THE CODE IS ENTERED WRONG, PRESS THE KEY TO RESET THE KEYPAD AND RE-ENTER THE CORRECT CODE (USE THE KEY TO RESET REMOTE KEYPADS) WITH TH
Specifications MECHANICAL Case dimensions: ELECTRICAL Voltage: Current: Backup Battery: Outputs: 15-1/4” W x 19” H x 4” D 16-24 Volts AC or 12-24 Volts DC 2000 mA @ 16 VAC maximum Externally charged 12 Volt DC source, 6 amp/hr minimum Relay Channels A-D Form “C” 3 Amps @ 30 Volts maximum Inputs: Four normally closed door sense inputs Four normally open exit request inputs Two WIEGAND reader inputs Three PBUS inputs Network: Three-wire network RADIO Frequency: Bandwidth: Sensitivity: Encoding: ENVIRONMENT
Troubleshooting System completely dead 1. No power from transformer. Check voltage at transformer terminals. 2. Check voltage at AE-2000 power terminal strip. Buzz on speaker 1. 2. 3. 4. 5. Check for 24 volt AC power shorted to wiring conduit. Check for telephone line shorted to ground. Verify that telephone wires are twisted pair. Verify that the AE-2000 is connected to earth ground. Check 16 VAC voltage at AE-2000 transformer terminals. Buzz on telephone line 1.