PRODUCT DESCRIPTION
The AM-MIO is an expandable input/output interface designed for use with Linear’s
AM-3, AE-1000, & AE-2000 access control systems. Housed in a lockable cabinet,
the basic AM-MIO consists of two modules: a power supply module (PSM) and a
relay/loop module (RLM). Up to three additional RLM modules can be added to fill the
five-position module “rack”. Each RLM module provides six Form “C” (normally open
& normally closed) 5-amp relays for outputs and eight supervised loop terminals for
inputs. With four RLM modules, the AM-MIO is capable of controlling 24 relay outputs
and 32 loop inputs. Each module has a rotary switch to select its unique remote device
address. The device address identifies each module to the system. Each module is
interconnected to the controller by daisy-chained cables.
Pushbuttons on the RLM module are provided for manually triggering each relay for
testing. Each relay has a red LED light to show when it’s energized. A two-color red/
green LED on the RLM module displays the status of the loop inputs. If all eight loops
are “normal” (not shorted or open) the indicator is green. If any of the eight loops are
“abnormal” (shorted or open) the indicator is red.
The power supply module distributes power to the RLM module(s). An external 16
VAC transformer powers the supply and provides charging current for a 12-volt backup
battery (up to 7 amp/hour capacity). Indicators on the power supply module display
its status. The green indicator lights when AC power is present and blinks when AC
power is absent. The yellow indicator lights when the backup battery is low. Special
power circuitry prevents fully discharging the backup battery. The status of the power
supply is checked regularly by the controller. The red DATA indicator lights when data
transfers. The red TAMPER indicator lights and the controller is signaled when the
optional magnetic tamper switch detects that the cabinet has been opened.
CABINET COMPONENTS
MODULE FEATURES KEY LOCK INSTALLATION (OPTIONAL) REMOVING MODULES
MOUNTING CABINET SETTING DEVICE ADDRESSES CONNECTING MODULES
INSTALLING MODULES CONNECTING TAMPER SWITCH (OPTIONAL) CONNECT TO ACCESS CONTROLLER
(760) 438-7000
USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340
www.linearcorp.com
PRINTER’S INSTRUCTIONS:
INSTR,INSTL,AM-MIO - LINEAR P/N: 218307 B - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 11.000” X 8.500” - SCALE: 1-1 - SIDE 1 OF 2
POWER
SUPPLY
MODULE
(PSM
)
NOTE: ILLUSTRATION SHOWS FOUR
RELAY/LOOP MODULES, ONLY ON
E
MODULE IS INCLUDED WITH THE AM-MIO
RELAY/LOOP MODULES (RLM)
(FOUR MODULES MAXIMUM
)
BACKUP BATTERY
12 VOLT 7 AMP/HOUR
MAXIMUM
(NOT INCLUDED)
MODULE
MOUNTING
RACKS
CAREFULLY ROUTE THE BATTERY
LEADS UNDER MODULE RACK
AS SHOW
N
1
2
SLIDE MODULES OUT
OF THE RACK
PSM
RL
M
1
2
3
PLACE COVER ON
CARPET AND PUNC
H
OUT KEY LOCK
KNOCKOUT
INSERT LOCK INTO COVER
TIGHTEN NUT
RELAY/LOOP
MODULE (RLM
)
POWER SUPPL
Y
MODULE (PSM
)
BACKUP
BATTER
Y
LEAD
S
DEVICE
ADDRESS
SELECTOR
DATA
POWER SUPPLY
STATUS
INDICATORS
TAMPER
LOW BATTER
Y
AC POWE
R
TAMPER
SWITCH
CONNECTOR
MODULE
CONNECTOR
CONTROLLER
CONNECTOR
POWER
TERMINALS
AUXILIARY
PBUS
TERMINAL
S
RELAY
STATUS
INDICATORS
LOOP STATUS
INDICATO
R
DEVICE ADDRESS
SELECTO
R
MODULE
CONNECTOR
S
RELAY TRIGGER
PUSHBUTTONS
RELAY
OUTPUT
TERMINALS
LOOP
INPU
T
TERMINALS
USE THE CABINET BOTTOM AS
A TEMPLATE TO MARK THE
FOUR KEYHOLE MOUNTING
HOLE
S
FOR RECESSED WIRING,
MARK WIRING SLOT
,
THEN CUT OUT HOLE
WITH DRYWALL SA
W
FOR CONDUIT WIRING
,
REMOVE ANY CABINE
T
KNOCKOUTS BEFORE
MOUNTING THE CABINE
T
USE THE APPROPRIAT
E
HARDWARE TO MOUNT
THE CABINE
T
NOTE:
PSM DEFAULT
ADDRESS IS "5"
NOTE:
RLM DEFAULT
ADDRESS IS "4
"
THE ARROW IN THE
SELECTOR SWITCH
SLOT POINTS TO
THE ADDRESS
NUMBER (ADDRESS
NUMBERS 1-6 AR
E
VALID)
SET EACH MODULE
TO A DIFFERENT
DEVICE ADDRESS
(ONLY REQUIRED IF
ADDRESS OTHE
R
THAN DEFAULT IS
DESIRED)
RELAY/LOOP
MODUL
E
POWER SUPPL
Y
MODUL
E
CONNECT POWER SUPPLY
TO RELAY/LOOP MODUL
E
WITH THE 10-WIRE CABL
E
1
2
3
REMOVE THE OPTIONAL JUMPER
FROM THE TAMPER SWITCH
CONNECTOR
INSTALL THE TAMPER SWITCH
IN THE BOTTOM CORNER OF
CABINET AND CONNECT TH
E
WIRE TO THE TAMPER
SWITCH CONNECTO
R
ATTACH THE MAGNET TO THE CABINET
COVER SO IT WILL ALIGN WITH TH
E
TAMPER SWITCH WHEN THE COVER IS
CLOSED
PLUG CABLE FROM AM-MIO PSM CONTROLLER
CONNECTOR INTO THE CONTROLLER'S AM-MIO
INTERFACE CONNECTOR (MODEL AM-3
CONTROLLER SHOWN)
TO AM-MIO PSM
OPTIONAL: USE THE PSM AUXILIARY PBUS TERMINALS TO
CONNECT TO THE CONTROLLER'S AUXILIARY PBUS TERMINALS.
REFERENCE THE PSM WIRING DIAGRAM. CABLE TYPE IS
BELDEN 9931 (300 FEET MAX. CABLE RUN) OR WEICO 9405
(500 FEET MAX. CABLE RUN).