DESCRIPTION
The DRQP is a high-sensitivity, short-range radio receiver that operates in
conjunction with the 9-inch local antenna (supplied) or the EXA-GP remote
antenna (not included). The DRQP is designed for use with automatic gate
operators or systems where a remote antenna is needed.
All of the Delta-3 transmitters, including the two and four-channel transmitters, are
compatible with the the DRQP. The Delta-3 radio format provides 256 different
digital codes. The codes are set using the 8-position coding switches in the units.
In order to avoid the posibility of duplicating codes in adjacent systems, factory
set codes should not be used. In addition, among the valid codes available, four
others should not be used. These include: all keys set ON or OFF and keys set
alternating ON/OFF. Receivers are normally powered with 24 volts AC/DC from
the gate operator.
The DRQP has a built-in “F” connector and is supplied with a 9-inch local antenna.
The EXA-GP Remote Antenna may be used to enhance the operational range of
the DRQP.
STEP 1A
Receiver code setting. Locate the receiver coding
switch which is recessed in the back of the receiver case. To set
a code, select any valid combination of ON and OFF positions for
the switch keys numbered 1 through 8. Use a paper clip to set
the eight keys on your receiver.
STEP 1B
Transmitter code setting. Locate the coding
switch on the transmitter and set the eight keys identical to those
on the receiver. Be sure they are both coded from left to right! Be
sure they are identical! If using a two or four-channel transmitter
refer to the coding instructions included with the transmitter for
proper system coding.
STEP 2
Connect receiver output. Connect the output
terminals (1 & 2) to the appropriate activation terminals on the
gate operator.
STEP 3
Connect receiver to 24V power. Connect the white
power input wires to the 24V and Common terminals on the gate
operator. If using DC power, gold wire (+), silver wire (-).
STEP 4
Optional Receiver mounting bracket. If the receiver
isn’t going to be mounted directly to the operator terminals, an
optional mounting bracket is supplied. It can be installed two ways
onto the DRQP case. Screw the bracket to a wall or stud and snap
the receiver onto it. Attach the 9-inch antenna or the EXA-GP
antenna coaxial cable to the “F” connector.
STEP 5
Test receiver.
Be sure gate area is clear.
Activate
each transmitter and verify that the receiver triggers the operator.
LIMITED WARRANTY
This product is warranted to the consumer against defects in material and workmanship for one year
from the date of purchase. This warranty applies to first retail buyers of new devices. Warrantor will
repair, or at its option, replace, any device it finds that requires service under this warranty, and will
return the repaired or replaced device to the consumer at the warrantor’s cost. For warranty service
and shipping instructions contact warrantor at the address shown below. Devices must be sent to
warrantor for service at owner’s expense. The remedies provided by this warranty are exclusive. Implied
warranties under state law are to the one year period of this written warranty. Some states do not allow
limitations on how long an implied warranty lasts, so the above limitation may not apply to you. In order
to be protected by this warranty, save your proof of purchase and send copy with equipment should
repair be required. This warranty gives you specific legal rights, and you may also have other rights
which vary from state to state.
All products returned for warranty service require a Return Product Authorization Number (RPA#).
Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.
IMPORTANT !!!
Linear radio controls provide a reliable communications link and fill an important need in portable
wireless signaling. However, there are some limitations which must be observed.
For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as
Part 15 devices. As such, they have limited transmitter power and therefore limited range.
A receiver cannot respond to more than one transmitted signal at a time and may be blocked by
radio signals that occur on or near their operating frequencies, regardless of code settings.
Changes or modifications to the device may void FCC compliance.
Infrequently used radio links should be tested regularly to protect against undetected interference
or fault.
A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale
distributor or dealer, and these facts should be communicated to the ultimate users.
Copyright © 1999 Linear Corporation 210402 C
SWITCHES IN
TRANSMITTER
THIS SWITCH
HAS 2, 3 & 6 ON
REMOVE BATTERY
ACCESS DOOR
CODING
SWITCH
SWITCHES IN
RECEIVER
THIS SWITCH
HAS 6, 3 & 2 ON
POWER INPUT
WIRE
CODING SWITCH
N
/
C
N
/
O
CO
M
.
LOCATION 1
ANTENNA
"F" CONNECTOR
N
/
C
N
/
O
C
O
M
.
BRACKET CAN
MOUNT IN TWO
PLACES
LOCATION 2
GATE
OPERATOR
24 V RADIO POWER
RELAY
DRQP
RECEIVER
COMMON
1
2
3
WALL
BUTTON
N/C
N/O
COM.
GATE
OPERATOR
24 V RADIO POWER
RELAY
DRQP
RECEIVER
COMMON
1
2
3
WALL
BUTTON
INPUT VOLTAGE REQUIREMENT
18 TO 24 VOLTS AC/DC
GOLD WIRE
SILVER
WIRE
PRESS TRANSM ITTER
BU TTO N TO TES T
W ARNING!
BE SURE GATE
AREA IS CLEAR
OF OBSTRUCTIONS