User Guide

11 EP Series User Programming Guide
Man-Trap
Door Lock Mode
Normal
Door Lock Mode
Doors (Cont.)
Door Lock Mode
1. Choose a Door Lock Name to name
the lock for logging.
2. Congure Door Lock Mode as
follows:
Normal: Lock activates in response
to a valid access request and REX
unlocks door for exit.
Locked: Does NOT grant access in
response to REX, card or code.
Locked w/REX: Remains in locked
mode, ONLY REX will activate lock.
Unlocked: Door will remain
unlocked at ALL times.
Man-Trap: Sets the door lock for
use in conjunction with another
door to create a man-trap passage. A Man-Trap will only allow one door to be opened if the other door is locked. When
Man-Trap is selected, Man-Trap Mode options appear:
Unlock: No security on Entry or Exit.
Secure Entry/Free Egress: Two options, both options use card access to enter the Exterior Door. Option 1 allows
free exit through the exterior door; Option 2 requires card access to exit through the exterior door.
Restricted Entry and Exit: Four options, all options use card access to enter the Exterior Door. Option 1 allows free
exit through the exterior door; Option 2 requires card access to exit through the interior door, Option 3 requires card
access to exit through the exterior door. Option 4 requires card access to exit through either door.
Pair Door: Select the second Man-Trap door that is closest to the secured area.
3. Select the Door’s Default Status. This setting will be determined by the lock type (energized or de-energized).
4. Assign Re-Lock on Open if desired. This will re-lock the door immediately upon opening the door.
5. Adjust Door Unlock Time if desired. This is the length of time the door relay is active after a valid access request.