TABLE OF CONTENTS Product Features........................................................................................................... 3 Jackshaft Operator Applications ................................................................................. 3 Preparation .................................................................................................................... 4 Figure 1 - Component Identification Pictorial .............................................................
PRODUCT FEATURES The purpose of this booklet is to provide assembly, installation and operation information concerning Model J-S & H-S Commercial Vehicular Garage Door Operators and related Accessory Products. NOTICE IT IS IMPORTANT THAT THIS INSTRUCTION MANUAL BE READ AND UNDERSTOOD COMPLETELY BEFORE INSTALLATION OR OPERATION IS ATTEMPTED.
PREPARATION WARNING ELECTRIC DOOR OPENERS ARE DESIGNED FOR DOORS IN GOOD WORKING CONDITION, PROPERLY COUNTERBALANCED AND PROPERLY ADJUSTED IN ACCORDANCE WITH THE DOOR MANUFACTURER'S INSTALLATION INSTRUCTIONS. Before starting the installation of the operator, the door must be in good working condition and properly counterbalanced. Inspect the door and track for loose or missing hardware. Test the door manually for balance and ease of operation. Lubricate door hinges and rollers.
IMPORTANT INSTALLATION INSTRUCTIONS! WARNING 5 TO REDUCE THE RISK OF SEVERE INJURY OR DEATH: READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS! • Install only on a properly operating and balanced garage door. A door that is operating improperly could cause severe injury. Have qualified service personnel make repairs to cables, spring assemblies and other hardware before installing the opener.
WARNING INSTALLATION INSTRUCTIONS SPRINGS, PULLEYS, CABLES AND MOUNTING HARDWARE USED TO BALANCE YOUR GARAGE DOOR ARE UNDER EXTREME TENSION AT ALL TIMES AND CAN CAUSE SEVERE INJURY OR DEATH IF DISTURBED. DO NOT ATTEMPT ADJUSTMENT. Figure 6, page 8 illustrates several positions suitable for mounting the operator; right hand or left hand, either wall mount or ceiling mount.
INSTALLATION INSTRUCTIONS CHAIN HOIST AND FLOOR DISCONNECT INSTALLATION 12” to 15” If the operator is furnished with a chain hoist (Model H-S), pass the hand chain over the chain wheel and through the chain guides on the operator clutch shaft (opposite end from the large pulley). Fasten the ends of the chain together by opening and re-closing one link using two pairs of pliers.
FIGURE 4 - OPERATOR MOUNTING POSITIONS Left Side Mount Ceiling Mount Center Mount Right Side Mount Direct Couple Ceiling Mount Wall Mount Wall Mount 100719 Figure 6
FIGURE 5 - OPERATOR DIMENSIONS - MODEL J-S & H-S 9 107841 Figure 7 - Dimensions Model H-S 108203 Figure 7A - Dimensions Model J-S
INSTALLATION INSTRUCTIONS WARNING TO AVOID RISK OF ENTRAPMENT AND POSSIBLE DAMAGE TO THE DOOR AND OPERATOR THE LIMITS MUST BE ADJUSTED BEFORE APPLYING POWER TO THE OPERATOR. SETTING THE LIMIT SWITCHES 1) With the cover open on the electrical enclosure, reference Figure 8 below. There are two (2) switches (A and B) mounted to the „V‟ bracket (F). The Close Limit switch (B) and the Open Limit switch (A) are mounted to the top side of the „V‟ bracket as shown.
INSTALLATION INSTRUCTIONS WARNING TO PREVENT THE RISK OF PERSONAL INJURY OR DEATH : • DISCONNECT POWER AT THE FUSE BOX BEFORE PROCEEDING. • ELECTRICAL CONNECTIONS MUST BE MADE BY A QUALIFIED INDIVIDUAL. • OBSERVE LOCAL ELECTRICAL CODES WHEN WIRING THE OPERATOR. WARNING: The J-S and H-S Series operators have been designed and constructed for use with voltages from 115 Volts AC to 480 Volts AC, in single or three phase.
DOOR EDGE and PHOTOELECTRIC INSTALLATION Note: See the door edge manufacturer‟s installation instructions for the complete installation procedure. See Figure 16 for connecting the edge to the operator. See Page 15 for proper setting of the selector switches. These switches must be properly set and an approved photoelectric device or approved door edge device connected to the operator to obtain B2 Mode of Operation, Momentary Contact to Close.
OPEN CLOSE STOP COM NO REV NC REV PHOTO COM SINGLE ILOCK 24 VAC COM INSTALLATION INSTRUCTIONS 13 ENTRAPMENT PROTECTION DEVICES WIRING INSTRUCTIONS Note A: Connect only one (1) approved entrapment protection device to terminals “Photo” and “Com”. If additional entrapment protection is desired connect additional photoelectric and door edges devices to “NC REV”, “NO REV” and “COM” terminals as shown here.
3/SINGLE BUTTON STATION / INTERLOCK FIELD WIRING D12 OPEN CLOSE C3 C11 MOTOR CONTROL BOARD C9 D8 R38 STOP R87 RADIO 24V COM RM3 RM2 RM1 VCC P7 R54 R30 PB3 C24 R29 PB2 D2 R57 R25 R26 PB1 C10 U4 C25 R65 U1 R3 C1 R2 U5 R5 D3 MOTOR CONTROL BOARD PCB 112695 REV B TSLK R84 14 R55 R56 C8 R94 R95 PB3 CLOSE STOP STOP CLOSE COM NC REV OPEN NO REV OPEN CLOSE STOP D12 COM NO REV NC REV PHOTO PB2 C1 C25 PB1 OPEN R3 PCB 112695 REV B TSLK R2 Figure 11 Single
OPERATION & ADJUSTMENT INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS FOR OWNER WARNING TO REDUCE THE RISK OF SEVERE INJURY OR DEATH: READ AND FOLLOW ALL INSTRUCTIONS! Understand all of the operating features of your door control system at the time of its installation. Your installing dealer will demonstrate them for you. NEVER let children operate or play with door controls. Keep the Remote Control (where provided) away from children.
OPERATION & ADJUSTMENT INSTRUCTIONS P4 SETTING THE SWITCH SELECTABLE OPERATING MODES Changing the Switch Selectable Operation Modes Settable P4 The following modes are selected by setting the on-board dip Switches switches, Figure 14 at right shows where the switches areK3 K5 K4 K2 HIGH VOLTAGE K6 Location located on the operator control board. For each Operational Mode, the switches are set to either ON or OFF according to the table at right below.
OPERATION & ADJUSTMENT INSTRUCTIONS Mid-Stop: Activation stops an opening door; momentary contact of open button at mid stop will restart door to full open position; if door is moving open, constant pressure on open button will bypass mid-stop. Auto Close Timer: N/A TS Operation Open Button: Momentary activation; open override of closing door. Close Button: Momentary activation. Stop Button: Momentary activation; stops open, close or reverse action.
OPERATION & ADJUSTMENT INSTRUCTIONS Mid-Stop Limit Setup This features provides a timing function to stop a door as it is traveling open at a Mid Stop position instead of the full open position. The door can then be moved to the full open position if desired by pressing the Open button. A single button input when the door is at the mid stop position will cause the door to begin moving in the close direction. The factory default is not set; the minimum run time to mid-stop limit is 6 seconds.
OPERATION & ADJUSTMENT INSTRUCTIONS CLUTCH ADJUSTMENT WARNING RISK OF ENTRAPMENT THAT MAY RESULT IN SERIOUS PERSONAL INJURY OR DEATH. DISCONNECT POWER TO THE OPENER BEFORE SERVICING OR MAKING ADJUSTMENTS. ENSURE DOORWAY IS CLEAR BEFORE STARTING TESTING OF UNIT. REQUIRED TO THE DOOR, DOOR SPRINGS OR DOOR OPERATOR MUST BE PREFORMED BY A QUALIFIED PROFESSIONAL DOOR INSTALLER.
OPERATION & ADJUSTMENT INSTRUCTIONS
OPERATION & ADJUSTMENT INSTRUCTIONS TESTING Following installation, the operator MUST be tested and respond correctly to all controls as specified on the wiring diagram. KEEP personnel and equipment clear of the area beneath the door when performing the tests. When testing the 3 -button wall station, first observe that each button operates the door in the direction indicated and that the STOP button performs that function.
WIRING DIAGRAM/SCHEMATIC - SINGLE PHASE CLOSE LIMIT WHITE GREY GREY RUN START BRAKE RED COM NO ORANGE ORANGE BLUE COM NO YELLOW OPEN LIMIT WHITE OVERLOAD DEVICE P4 BLACK L1 WHITE N K5 HIGH VOLTAGE K3 K4 K6 GROUND COM OLS TR3 CLS COM SW1 P1 S4 S3 S2 S1 POWE MO4 MO3 MO2 MO1 ILK P2 R89 TR1 24V P3 R49 R10 R62 R22 R47 C16 COM LINE R20 R82 R17 R18 D3 R13 R14 R65 R1 R21 C10 R57 C24 D8 C9 R31 U1 RM2 RM1 VCC C30 P7 R58 R11 R12 R87 R15 R16 R6 R7 2
WIRING DIAGRAM/SCHEMATIC - THREE PHASE CLOSE LIMIT WHITE GREY GREY BRAKE + RED COM NO ORANGE ORANGE BLUE COM NO +CONNECTION SHOWN FOR 208 & 230V - FOR 460V SEE MOTOR DIAG. ON INSIDE OF CONT.
NOTES
PARTS IDENTIFICATION Ref Part# Description Parts Description 1 009221 Shaft Collar, 1” 2 008071 Flange Bearing, 3/4” 105933 Frame Assembly w/Shafts.
MODEL : J_ _ _ _S VOLTS : _____ 26 SPECIFICATIONS SPECIFICATIONS MODEL : H _ _ _ _ S HP:_____ VOLTS : _____ PHASE : _____ * UL AND CANADIAN UL LISTED * HIGH STARTING TORQUE, CONTINUOUS DUTY MOTOR * MOTOR OVERLOAD PROTECTION * CLASS 2 (24 VOLT) CONTROL CIRCUIT * SOLENOID BRAKE * SOLID STATE MOTOR CONTROL CIRCUITRY WITH ADVANCED OPERATIONAL FEATURES STANDARD * THREE BUTTON CONTROL: OPEN, CLOSE, STOP * WIRED TO ACCEPT REVERSING EDGE INPUT * HEAVY GAUGE, POWDER-COATED STEEL FRAME AND POWDER COATED CONTR